3. Remove four plastic, thread-protecting plugs from bottom of
dispenser.
4. Attach dispenser to base stand with supplied hardware (Fig. 5).
NOTICE!
If installing optional Drip Tray Drain Kit, refer to instructions
included with the Drip Tray Drain Kit.
5. Connect water line. Recommended routing (Fig. 6) allows easy access
to water for cleaning and sanitizing procedure.
6. If installing the optional internal water filter*, please see
Internal Water Filter Installation on page 11
If not, proceed to step 7.
* If your dispenser has the internal water filter option, the water filter must
be installed for the dispenser to operate. Because internal components
will need to be accessed for both procedures, Follett recommends
installing the water filter just prior to initial sanitizing.
7.
Connect power supply.
8. Sanitize the dispenser prior to use (see the Initial Sanitizing Kit
instructions shipped with this unit).
9. Secure unit to wall or cove molding with supplied bracket (Fig. 7) to
prevent tipping.
Note: Fasteners must be supplied by installer.
WARNING!
Freestanding unit must be secured to wall to prevent tipping.
Failure to do could result in personal injury or damage to the
unit.
10
Dispenser and Ice Machine 230 V/50 Hz and 220 V/60 Hz
Optional
before proceeding.
Fig. 5
Fig. 6
91.4 cm (3')
Plug
Valve
1/4" MPT
Fig. 7
X4