Download Print this page

Technical Data - Graco HIGH-FLO Viscount II 300 Series Instructions-Parts List Manual

Wall mount or floor stand circulation packages

Advertisement

Viscount II 300 Pumps, Models 96A390, 96A645, 96A897, and 96A898
Category
Maximum Fluid Working Pressure
Maximum Hydraulic Fluid Pressure
Fluid Flow at 60 Cycles per Minute
Cycles Per Liter (gallon)
Maximum Recommended Pump
Speed
Maximum Hydraulic Motor Fluid
Temperature
Wetted parts
VitonR is aRregistered trademark of the Du Pont Co.
To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow
(lpm/gpm) and operating hydraulic pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale to read fluid outlet
pressure.
Fluid Outlet Pressure
psi
cycles per minute
MPa, bar
8
15
300
2.1, 21
A
250
1.8, 17.5
200
B
1.4, 14
150
1.0, 10
100
C
0.7, 7
50
0.35, 3.5
0
0
8
16
gpm
liters/minute
30
60
FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)
22
310570

Technical Data

Data
2.1 MPa, 21 bar (300 psi)
10.3 MPa, 103 bar (1500 psi)
237 liter/min (63 gpm)
0.24 (0.93)
60 cycles per minute
54_C (134_F)
Stainless Steel, PTFE, Ultra High Molecular Weight Polyethylene R
Performance Charts
A
10.3 MPa, 103 bar (1500 psi) hydraulic pressure
B
7.2 MPa, 72.4 bar (1050 psi) hydraulic pressure
C
4.1 MPa, 41 bar (600 psi) hydraulic pressure
23
30
38
46
53
24
32
40
48
56
91
121
151
181
212
To find Motor Hydraulic Oil Consumption (l/min or gpm) at a specif-
ic fluid flow (l/min or gpm):
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with hydraulic oil consumption
curve (dashes). Follow left to scale to read hydraulic oil consump-
tion.
Hydraulic Oil Consumption
gpm
cycles per minute
l/min
8
15
16
60
12
45
8
30
4
15
0
0
8
16
gpm
liters/minute
30
60
FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)
23
30
38
46
53
24
32
40
48
56
91
121
151
181
212

Advertisement

loading