Care And Maintenance; Troubleshooting; Warranty - Utilitech 7105-06 Instructions Manual

Decorative ventilation fan with led light
Hide thumbs Also See for 7105-06:
Table of Contents

Advertisement

Available languages

Available languages

CARE AND MAINTENANCE

WARNING: Disconnect power supply before servicing. See SAFETY INFORMATION before proceeding.
Routine maintenance should be done at least once a year.
• Wash glass globe with mild soap and water, dry with a cloth.
• Remove excess dirt and dust from the fan housing with a vacuum cleaner.
• Do not use solvents, thinner or harsh chemicals for cleaning the fan.
• Do not allow water to enter the motor.
• Do not immerse resin parts in water over 140º F.

TROUBLESHOOTING

PROBLEM
The fan seems louder
than it should
The fan is not
clearing the room
LIMITED 5-YEAR WARRANTY
If this product fails due to a defect in materials or workmanship at any time during the first FIVE years of ownership, the
manufacturer will replace it free of charge, postage-paid at their option. This warranty does not cover products that have
been abused, altered, damaged, misused, cut or worn. This warranty does not cover use in commercial applications. Use
only manufacturer-supplied genuine warranty repair replacement parts to repair this fan. Use of non-genuine repair parts
will void your warranty. The manufacturer DISCLAIMS all other implied or express warranties including all warranties of
merchantability and/or fitness for a particular purpose. As some states do not allow exclusions or limitations on an implied
warranty, the above exclusions and limitations may not apply. This warranty gives you specific legal rights, and you may
have other rights that vary from state to state.
This warranty is limited to the replacement of defective parts only. Labor charges and/or damage incurred during installation,
repair, replacement as well as incidental and consequential damages connected with the above are excluded. Any damage
to this product as a result of neglect, misuse, accident, imporper installation or use other than the purpose SHALL VOID
THIS WARRANTY.
Shipping costs for return product as part of a claim on the warranty must be paid for by the customer.
Inquiries regarding warranty claims can be directed to 1-866-994-4148, 8 a.m. - 6 p.m., EST, Monday - Thursday, 8 a.m. - 5 p.m.,
EST, Friday.
POSSIBLE CAUSE
CFM too great
Damper not working properly or damaged
Bend in duct too close to fan discharge
Fan discharge reduced to fit smaller duct
Fan housing not securely attached
Insufficient intake airflow within room
Insufficient CFM
CORRECTIVE ACTION
Be sure the CFM rating on the fan matches
the size of your room
Check damper to ensure it is opening and
closing properly. If the damper has become
damaged, please call Customer Service
Be sure you do not have any sharp bends in
duct closer than 18 in. to the fan discharge
Use recommended size ducting to reduce fan
noise
Be sure the fan is securely attached
to your ceiling joists
Be sure a door or window is slightly ajar or
opened to allow airflow. The fan is not able
to draw air out of the room without enough
airflow to draw from
Be sure the CFM rating on the fan matches the
requirements for your room size
NOTE: Using a tissue is not an accurate
method for determining if the fan is operating
properly. If the fan clears steam from the room
within approximately 15 minutes of completing
your shower, then the fan is operating properly
12