Cycle Operation Mode for each battery.

Cycle Mode Charge/Discharge of POLARON AC/DC SPORTS
LiPo, LiIon, LiFe, Pb
NiCd, NiMH
25
(2) Cycle Mode and Delay Time
Charge Option of cycle mode
Discharge Option of cycle mode
Configure the Delay time for Charge/Discharge option and
operation start. The Charge/Discharge option could be
picked tapping repeatedly. According to the batteries, the
Charge/Discharge options are following.
Press the
Delay time for operation
It will be available from 1 to 150 min. This is a reserved
timer for starting the Charge/Discharge cycle.
CC-CV: Normal Charge
NORMAL: Normal Discharge option
LINEAR : Discharge for a specific current to the final voltage
AUTO: Optimal Charge/Discharge Automatically
NORMAL: Normal Charge/Discharge option
LINEAR: Charge/Discharge for a specific current to the final voltage
(3) Cycle operation screen
Screen for the cycle start. According to the configured volt-
age and current values, it will be presented.
The configured current could be limited for the capacity. Max
charge is 120W and max discharge is 30W.
The current cycle count is presented.
Screen for the cycle operation.
The operation could be verified by blinking.
The current operation status is presented by +/-
Tap the current part and you can check the related data.
Please refer to the data view page.
button for starting the cycle.