Delta Agema Series Installation Manual
Delta Agema Series Installation Manual

Delta Agema Series Installation Manual

Aggregation switch
Hide thumbs Also See for Agema Series:

Advertisement

Quick Links

Delta Networking – Agema Family
AGC7648S V1 Aggregation Switch
- AGC7648S V1
- AGC7648SL V1
Installation Guide
agema.deltaww.com

Advertisement

Table of Contents
loading

Summary of Contents for Delta Agema Series

  • Page 1 Delta Networking – Agema Family AGC7648S V1 Aggregation Switch - AGC7648S V1 - AGC7648SL V1 Installation Guide agema.deltaww.com...
  • Page 2 All trademarks and logos mentioned in this guide are the properties of their respective holders. Copyright © Delta Electronics, Inc. All rights reserved. Regulatory and Safety Information This product has been tested in accordance to, and complies with the following safety standards and electromagnetic compatibility (EMC) inspection standards.
  • Page 3 Important! This product is intended for installation only in the RESTRICTED ACCESS AREA ACCESSIBLE only to SKILLED PERSONS and INSTRUCTED PERSONS with the proper authorization. • Access is through the use of a lock or tool and key, or other means of security, and is controlled by the authority responsible for the location.
  • Page 4 CAUTION Lithium Battery Caution Danger of explosion if battery is incorrectly replaced. Replace only with same or equivalent type. Dispose batteries according to manufacturer’s instructions. Disposal of a BATTERY into fire or a hot oven, or mechanically crushing or cutting of a BATTERY, that can result in an EXPLOSION.
  • Page 5 MISE EN GARDE Mise en garde concernant la pile au lithium Risque d’explosion si la pile est remplacée incorrectement. Remplacez-la avec une pile semblable ou de même type uniquement. Éliminez les piles selon les directives du fabricant. L’élimination de la PILE dans un feu, un four chaud ou un broyeur mécanique peut provoquer une EXPLOSION.
  • Page 6: Table Of Contents

    Table of Contents Chapter 1: Introduction -------------------------------------------------------------------1 1.1 Overview ------------------------------------------------------------------------------------ 1 1.2 Package Content ------------------------------------------------------------------------- 1 1.3 Features------------------------------------------------------------------------------------- 2 Chapter 2: Appearance and Mechanism --------------------------------------------3 2.1 Product Overview ------------------------------------------------------------------------- 3 2.2 LED Identification ------------------------------------------------------------------------- 4 2.3 System Requirements ------------------------------------------------------------------- 7 2.4 Data Center Deployment --------------------------------------------------------------- 8 2.5 Power Supply Modules ------------------------------------------------------------------ 9 2.6 Fan Tray Module -------------------------------------------------------------------------10...
  • Page 7: Chapter 1: Introduction

    Chapter 1: Introduction Overview AGC7648S V1 is a ToR/Leaf and EoR switch with deep buffers for data center deployment or as mobile access/aggregation switching and edge routing in service provider network. AGC7648S V1 is not only offering 100GbE uplink ports but also supporting virtualization features.
  • Page 8: Features

    Features The following lists the key main features of AGC7648S V1 switch: • 48 x 10GbE SFP+ and 6 x 100GbE QSFP28 ports, support splitter cable • 1 x RJ45 OOB management port • 1 x RJ45 Console port • 1 x USB port •...
  • Page 9: Chapter 2: Appearance And Mechanism

    Chapter 2: Appearance and Mechanism Product Overview 2.1.1 Front View Management port x 1 QSFP28 port x 6 Console port x 1 SFP+ port x 48 (Figure 2-1: Front View) 2.1.2 Rear View 4 Fan tray slots USB port x 1 Reset x 1 Secondary PSU PSU x 1...
  • Page 10: Led Identification

    LED Identification This section provides an overview of the front and rear LEDs. 2.2.1 Front LEDs Upper QSFP28 Port LED Upper SFP+ Port LED Power LED System LED Fan LED Lower SFP+ Port LED Lower QSFP28 Port LED (Figure 2-3: Front LED Identification) Description Solid Green –...
  • Page 11 Chapter 2 • Appearance and Mechanism Description LED1 (Solid Lighting – Linkup; Blinking – Activity) Solid Green – 100G operation • Solid Amber – 40G operation • Solid Blue – 25G operation • Solid Purple – 10G operation • Off – No Link •...
  • Page 12 2.2.2 Rear LEDs Fan tray LED Power Supply LED (Figure 2-4: Rear LED Identification) Description Solid Green – FAN is operating normally • Fan tray LED Solid Red – Fan failure • Solid Green – PSU is operating normally • Power Supply Solid Red –...
  • Page 13: System Requirements

    Chapter 2 • Appearance and Mechanism System Requirements Component Requirement System requirements Switch fabric capacity Non-blocking full wire speed on all packet sizes Forwarding architecture Store and forward or cut-through • 148,000,000 pps (100GbE) Port packet forwarding rate • 59,520,000 pps (40GbE) (at 64 Bytes) •...
  • Page 14: Data Center Deployment

    Data Center Deployment The following figure illustrates the converged Ethernet data center deployment. Internet VPN/MPLS Spine Data Center Data Center VPN/MPLS VPN/MPLS 100GbE Fabric Internet Leaf 10GbE Fabric Rack 1 Rack N End of Row (Figure 2-5: Data Center: Spine and Leaf Deployment) Mobile Access Network AGC7648S V1...
  • Page 15: Power Supply Modules

    Chapter 2 • Appearance and Mechanism Power Supply Modules The power supply modules are hot-swappable power supply units (PSUs) for the switch. You can install up to two PSUs. The PSUs operate in a load-sharing mode and provides 1+1 redundancy. (Figure 2-7: Power Supply Unit) NOTE: 1+1 redundancy is a system where a switch power supply is backed up by...
  • Page 16: Fan Tray Module

    Fan Tray Module The fan tray module is part of the switch air cooling system that provides cooling for the switch. You must install the fan tray module in the switch that matches the airflow direction of the installed power supply unit. (Figure 2-8: Fan Tray Module) AGC7648S V1 Aggregation Switch...
  • Page 17: Chapter 3: Installation

    Chapter 3: Installation Mounting This switch can be mounted in a standard 19-inch equipment rack. Prior rack mounting the switch, pay particular attention to the following factors: • Mechanical Loading: Do not place any equipment on top of a rack-mounted unit. •...
  • Page 18 (Figure 3-2: Securing the Front Mounting Bracket) 3. From the rear side of the device, install the rear mounting brackets on both sides of the device. (Figure 3-3: Installing the Rear Mounting Brackets) 4. Align the rear mounting brackets to the rack holes. Then secure the rear mounting brackets to the rack by using two M6 screws.
  • Page 19: Installing An Optional Transceiver And Cable

    Chapter 3 • Installation Installing an Optional Transceiver and Cable The SFP+ slots support the following optional transceivers and cables: • 10GBASE-SR • 10GBASE AOC • 10GBASE-LR • 10GBASE DAC The QSFP28 slots support the following optional transceivers and cables: •...
  • Page 20 NOTE: • SFP+, QSFP, or QSFP28 transceivers are hot-swappable. The switch does not need to be powered off before installing or removing a transceiver. However, always first disconnect the network cable before removing a transceiver. • SFP+, QSFP, or QSFP28 transceivers are not provided in the switch package.
  • Page 21: Connecting To The Console Port

    Chapter 3 • Installation Connecting to the Console Port This port is used to connect a console device to the switch through a nullmodem serial cable. The console device can be a PC or workstation running a VT-100 terminal emulator, or a VT- 100 terminal.
  • Page 22 3. Check the PSU and front-panel LEDs as the device is powered on to be sure that AC power is being received and the Power LED is on. If not, check that the power cable is correctly plugged in. 4. Repeat steps 1 and 2 when a second PSU module is installed. Two installed PSU modules operate in a load-sharing mode and provide 1+1 redundancy.
  • Page 23 Chapter 3 • Installation 3. Check the PSU and front-panel LEDs as the device is powered on to be sure that DC power is being received and the Power LED is on. If not, check that the power cable is correctly plugged in.
  • Page 24 4. Repeat steps 1 and 2 when a second PSU module is installed. Two installed PSU modules operate in a load-sharing mode and provide 1+1 redundancy. The above description for equipment installation reference only. AGC7648S V1 Aggregation Switch...
  • Page 25: Chapter 4: Making The Network Connections

    Chapter 4: Making the Network Connections The AGC7648S V1 switch is designed to provide high-speed, lossless Ethernet connections between server racks through its 10G SFP+ or 100G QSFP28 ports. This chapter describes how to make network connections to the switch. Twisted-pair Connections The switch’s Management port connection requires an unshielded twisted-pair (UTP) cable with RJ-45 connectors at both ends.
  • Page 26: Fiber Optic Connections

    Fiber Optic Connections Optional 10G SFP+ or 100G QSFP28 transceivers can be used for fiber connections from the switch to other network devices in the data center. An SFP+ or QSFP28 transceiver may also be used for long distance connections to devices at another site. WARNING: •...
  • Page 27: Ethernet Cabling

    Chapter 4 • Making the Network Connections (Figure 4-3: Making QSFP28 Port Fiber Connection) Ethernet Cabling To ensure proper operation when installing the switch into a network, make sure that the current cables are suitable for 10BASE-T, 100BASE-TX or 1000BASE-T operation. Check the following criteria against the current installation of your network: •...
  • Page 28: Appendix 1 : Technical Specifications

    Appendix 1 : Technical Specifications Item Description Key components Switch controller BCM88375 x 1 BCM5461S x 1 Intel Broadwell-DE D1527 Quad Core Flash ROM 32 MB SPI Flash System memory 16GB DDR4 SO-DIMM x 2 Storage 128GB m.2. SSD AST2520 Packet buffer 4GB GDDR5 •...
  • Page 29: Appendix 2 : Warranty

    During the warranty period, products for which proper claims are made will, at Delta’s option, be repaired or replaced at Delta’s expense. Customers may contact Delta’s technical support for warranty services, which may be provided either through Resellers or by Delta directly.
  • Page 30 Any product returned to Delta or Resellers without prior Return Material Authorization (RMA) from Delta will be considered an unauthorized return, and you will not receive any repair or replacement for the product and Delta will not ship the product back to you. The authorization will be provided through the e-mail: AgemaTechSupport@deltaww.com.

This manual is also suitable for:

Agema agc7648s v1 seriesAgema agc7648s v1Agema agc7648sl v1