  • Page 1 Delta Networking – Agema Family AGC032 Spine Switch Installation Guide agema.deltaww.com...
  • Page 2 All trademarks and logos mentioned in this guide are the properties of their respective holders. Copyright © Delta Electronics, Inc. All rights reserved. Regulatory and Safety Information This product has been tested in accordance to, and complies with the following safety standards and electromagnetic compatibility (EMC) inspection standards.
  • Page 3 Important! This product is intended for installation only in the RESTRICTED ACCESS AREA ACCESSIBLE only to SKILLED PERSONS and INSTRUCTED PERSONS with the proper authorization. • Access is through the use of a lock or tool and key, or other means of security, and is controlled by the authority responsible for the location.
  • Page 4 CAUTION Lithium Battery Caution Danger of explosion if battery is incorrectly replaced. Replace only with same or equivalent type. Dispose batteries according to manufacturer’s instructions. Disposal of a BATTERY into fire or a hot oven, or mechanically crushing or cutting of a BATTERY, that can result in an EXPLOSION.
  • Page 5 MISE EN GARDE Mise en garde concernant la pile au lithium Risque d’explosion si la pile est remplacée incorrectement. Remplacez-la avec une pile semblable ou de même type uniquement. Éliminez les piles selon les directives du fabricant. L’élimination de la PILE dans un feu, un four chaud ou un broyeur mécanique peut provoquer une EXPLOSION.
  • Page 6: Table Of Contents

    Table of Contents Chapter 1: Introduction -------------------------------------------------------------------1 1.1 Overview ------------------------------------------------------------------------------------ 1 1.2 Package Content ------------------------------------------------------------------------- 1 1.3 Features------------------------------------------------------------------------------------- 2 Chapter 2: Appearance and Mechanism --------------------------------------------3 2.1 Product Overview ------------------------------------------------------------------------- 3 2.2 LED Identification ------------------------------------------------------------------------- 4 2.3 System Requirements ------------------------------------------------------------------- 7 2.4 Data Center Deployment --------------------------------------------------------------- 8 2.5 Power Supply Modules ------------------------------------------------------------------ 9 2.6 Fan Tray Module -------------------------------------------------------------------------10...
  • Page 7: Chapter 1: Introduction

    Chapter 1: Introduction Overview The AGC032 is a high performance and high density next generation switch designed for hyper-scale data center network and 400G Ethernet is a key technology to change the infrastructure to support the mobile and cloud-based application. AGC032 is also designed with high speed, low latency data transmission and state-of-the-art instrumentation feature supported which provides comprehensive support on layer 2 and layer 3 features, including SNMP, Spanning Tree, VLAN, QinQ, Trunk, QoS, RIP, OSPF, IGMP, Access Control, Open...
  • Page 8: Features

    Features The following lists the key main features of AGC032 switch: • 32 x 400GbE QSFP-DD ports, support splitter cables • 2 x 10GbE SFP+ management ports • 1 x RJ45 OOB management port • 1 x RJ45 Console port •...
  • Page 9: Chapter 2: Appearance And Mechanism

    Chapter 2: Appearance and Mechanism Product Overview 2.1.1 Front View USB port x 1 SFP+ ports x 2 Management port x 1 QSFP-DD ports x 32 RJ-45 Console port x 1 (Figure 2-1: Front View) 2.1.2 Rear View Redundant PSU x 2 6 Fan tray slots (Figure 2-2: Rear View) NOTE:...
  • Page 10: Led Identification

    LED Identification This section provides an overview of the front and rear LEDs. 2.2.1 Front LEDs Upper SFP+ Port LED Upper QSFP-DD Port LED Management Port LED Power 1 LED Power 2 LED System LED Fan LED Lower SFP+ Port LED Lower QSFP-DD Port LED (Figure 2-3: Front LED Identification) Description...
  • Page 11 Chapter 2 • Appearance and Mechanism Description LED 2 (Solid Lighting – Linkup; Blinking – Activity) Solid Green – 100G Operation • Solid White – 50G Operation • Off – No Link • 400GE LED3 (Solid Lighting – Linkup; Blinking – Activity) QSFP-DD Solid Purple –...
  • Page 12 2.2.2 Rear LEDs AC Input LED DC Output LED FAULT LED Fan LED (Figure 2-4: Rear LED Identification) Description Solid Green – Input voltage is present and normal • AC Input LED Off – No input voltage • Solid Green – Output voltage is present and normal •...
  • Page 13: System Requirements

    Chapter 2 • Appearance and Mechanism System Requirements Component Requirement System Requirements Switch Fabric Capacity Non-blocking full wire speed on all packet sizes Forwarding Architecture Store and forward or cut-through • 595,200,000 pps (400GbE) • 148,800,000 pps (100GbE) Port Packet Forwarding Rate •...
  • Page 14: Data Center Deployment

    Data Center Deployment The following figure illustrates 400GbE switch in Super Spine for Data Center CLOS architecture. AGC032 AGC032 AGC032 AGC032 Super Spine 400GbE Spine 400GbE Spine BGP/BFD/ECMP based Network Spine Spine Leaf Leaf POD 1 POD N (Figure 2-5: PoD based Hyper-Scale Data Center Deployment) AGC032 Spine Switch...
  • Page 15: Power Supply Modules

    Chapter 2 • Appearance and Mechanism Power Supply Modules The power supply modules are hot-swappable power supply units (PSUs) for the switch. You can install up to two PSUs. The PSUs operate in a load-sharing mode and provides 1+1 redundancy. (Figure 2-6: Power Supply Unit) NOTE: 1+1 redundancy is a system where a switch power supply is backed up by...
  • Page 16: Fan Tray Module

    Fan Tray Module The fan tray module is part of the switch air cooling system that provides cooling for the switch. You must install the fan tray module in the switch that matches the airflow direction of the installed power supply unit. (Figure 2-7: Fan Tray Module) AGC032 Spine Switch...
  • Page 17: Chapter 3: Installation

    Chapter 3: Installation Rack Mounting This switch can be mounted in a standard 19-inch equipment rack surface. Prior rack mounting the switch, pay particular attention to the following factors: • Mechanical Loading: Do not place any equipment on top of a rack-mounted unit. •...
  • Page 18 (Figure 3-2: Assembling the Outer Rail) 3. Mount the switch to the rack cabinet. Slide the inner rails on the switch into the middle rails and push the switch all the way to the rear of the rack. Use one M5 rack-mounting screw to fasten the front bracket to the rack cabinet.
  • Page 19: Installing An Optional Qsfp28/Qsfp-Dd Transceiver

    Chapter 3 • Installation Installing an Optional QSFP28/QSFP-DD Transceiver The QSFP-DD slots support the following optional QSFP28/QSFP-DD transceivers: • 400G BASE-SR8 • 100G BASE-SR4 • 400G BASE-LR8 • 100G BASE-LR4 • 400G BASE-DR4 • 100G BASE AOC (Active Optical Cable) •...
  • Page 20: Installing An Optional Sfp+ Transceiver

    Installing an Optional SFP+ Transceiver The SFP+ slots support the following optional transceivers and cables: • 10GBASE-SR • 10GBASE AOC • 10GBASE-LR • 10GBASE DAC (Figure 3-5: Inserting an SFP+ Transceiver into a Slot) To install an SFP+ transceiver, follow these steps: 1.
  • Page 21: Connecting To The Console Port

    Chapter 3 • Installation Connecting to the Console Port This port is used to connect a console device to the switch through a null modem serial cable. The console device can be a PC or workstation running a VT-100 terminal emulator, or a VT-100 terminal.
  • Page 22 4. Repeat steps 1 and 2 when a second PSU module is installed. Two installed PSU modules operate in a load-sharing mode and provide 1+1 redundancy. 3.5.2 Installing a DC Power Supply DC power cord for DC source connection 1. Insert the power cable plug directly into the DC socket of a PSU located at the back of the switch.
  • Page 23: Chapter 4: Making The Network Connections

    Chapter 4: Making the Network Connections The AGC032 switch is designed to provide high-speed, lossless Ethernet connections between server racks through its 400G QSFP-DD ports. This chapter describes how to make network connections to the switch. Twisted-pair Connections The switch’s Management port connection requires an unshielded twisted-pair (UTP) cable with RJ-45 connectors at both ends.
  • Page 24: Fiber Optic Connections

    Fiber Optic Connections Optional 400G QSFP-DD transceivers can be used for fiber connections from the switch to other network devices in the data center. A QSFP-DD transceiver may also be used for long distance connections to devices at another site. WARNING: •...
  • Page 25: Ethernet Cabling

    Chapter 4 • Making the Network Connections Ethernet Cabling To ensure proper operation when installing the switch into a network, make sure that the current cables are suitable for 10BASE-T, 100BASE-TX or 1000BASE-T operation. Check the following criteria against the current installation of your network: •...
  • Page 26: Appendix 1 : Technical Specifications

    Appendix 1 : Technical Specifications Item Description Key Components Switch Controller BCM56980 x 1 LAN Controller Intel I210-AT x 1 Intel Broadwell D1527 Quad Core Flash ROM 32MB SPI NOR Flash x2 System Memory 16GB DDR4-SO-DIMM x2 Storage 64GB m.2. SSD x2 AST2520 ST33HTP Power Supply...
  • Page 27 Appendix 1 • Technical Specifications Item Description Environmental Specifications Operating Temperature 0 to 40°C Storage Temperature -20 to 70°C Operating Humidity 10 to 90% RH Storage Humidity 5 to 95% RH...
  • Page 28: Appendix 2 : Warranty

    During the warranty period, products for which proper claims are made will, at Delta’s option, be repaired or replaced at Delta’s expense. Customers may contact Delta’s technical support for warranty services, which may be provided either through Resellers or by Delta directly.
  • Page 29 Any product returned to Delta or Resellers without prior Return Material Authorization (RMA) from Delta will be considered an unauthorized return, and you will not receive any repair or replacement for the product and Delta will not ship the product back to you. The authorization will be provided through the e-mail: AgemaTechSupport@deltaww.com.

This manual is also suitable for:

Agema agc032

Table of Contents