Replacing Magnet Armature (Nc Function); Replacing Manual Assisted Actuation Device - Beko DRYPOINT AC Series Installation And Operating Manual

Cold-regenerated adsorption dryer with dew point control
Table of Contents

Advertisement

EN
Installation and operating manual

7.5.4.3. Replacing magnet armature (NC function)

Depressurise the valve and shut down the power supply.
Disengage the spring bracket and remove the solenoid. If the O-ring on the magnet sleeve has become brittle,
replace it. Remove the size 22 screw element. Remove the magnet sleeve together with the screw element and the
spring bracket. Remove the O-ring from the groove.
Replace the pressure spring and the magnet armature. Slide a new O-ring onto the collar of the magnet sleeve and
mount the magnet sleeve as shown in the drawing. When the screw element is screwed in, the O-ring is pushed
into the correct position to seal the device properly. Tightening torque for screw element: 20 Nm ± 10 %.

7.5.4.4. Replacing manual assisted actuation device

Depressurise the valve and shut down the power supply.
Disengage the spring bracket and remove the solenoid. If the O-ring on the magnet sleeve has become brittle,
replace it. Remove the size 22 screw element. Remove the magnet sleeve together with the screw element and the
spring bracket. Remove the O-ring from the groove.
Replace the manual assisted actuation device. Slide a new O-ring onto the collar of the magnet sleeve and mount
the magnet sleeve as shown in the drawing. The collar of the magnet sleeve must engage in the groove of the
manual assisted actuation device. By screwing in the screw element, the O-ring is pushed onto the collar of the
magnet sleeve to seal the device.
Tightening torque for screw element: 20 Nm ± 10 %.
7.5.4.5. Figure: Spare parts
Parts marked with "NC" and "NO" are included in the wearing parts kit (see "7.8. Spare parts").
42