Specifications - Ashly CA Series Operating Manual

2- and 4-channel
Table of Contents

Advertisement

CA Amplifier • Operating Manual

Specifications

Distortion (SMPTE, typical)
Distortion (THD-N, typical, 8 Ohm,
10dB below rated power, 20Hz-20kHz
Signal to Noise, 26dB input sensitivity,
20Hz-20kHz, unweighted
Frequency Response
Channel Separation
(dB from full output, 1kHz)
Damping Factor (8 Ohm load, <1kHz)
Balanced Input Connector (per channel)
Input Impedance
Maximum Input Level
Bridge Mode Switch
(per channel pair)
Remote DC Level Control
(G, CV, V+ per channel)
DIP Switch settings (per channel)
Switches 1-2: Input Gain
Switch 3: Output Clip Limiter
Switch 4: Input High Pass Filter
DIP Switch settings (global)
Switch 5: Front Panel Disable
Switch 6: Standby Polarity
Standby Contact Closure
Speaker Output Connector
Front Panel Indicators
Power Switch LED (white)
Clip/Mute LED (red)
Signal LED (green)
Current LED (green)
Temp LED (yellow)
Bridge LED (green)
Protect LED (red) -see troubleshooting
section for protect LED error codes
(continued)
<0.5%
<0.5%
>98dB (50x models),
>101dB (1.0x models),
>103dB (1.5x models)
20Hz-20kHz, +/-0.05dB
-75dB
>250
Euroblock (3.5mm),
1/4" TRS and XLR Combo jack
10k Ohm
+21dBu
In for bridged mode,
Out for stereo
Euroblock (3.5mm), V+ is fully
on, G is fully attenuated
26dB, 32dB, 38dB, 1.4V
On, Off
80Hz 2nd order HPF - On, Off
On, Off
High (standby when open), Low
(standby when closed)
Euroblock (3.5mm)
Euroblock (7.62mm)
On, Off, Standby (flashing)
On at 95% max output
(0.5dB below max), Mute
On at 25% max output voltage
(-12dB)
On at >2 Amps to speaker load
On when thermal counter-
measures are being applied
Per Channel Pair - On, Off
On for fault condition counter-
measures or shut-down, Off
Disable LED (yellow)
Attenuators
Remote Control Options
Amplifier Protection
Cooling
Power Cable Connector
Operating Voltage Range (50-60Hz,
85VAC or 170VAC min startup)
Environmental
Unit Dimensions (all models)
Unit Weight by Model
Shipping Dimensions (all models)
Shipping Weight by Model
Safety/Compliance
On when front panel controls are
disabled, Off
Per channel: front panel,
Fully off = Mute
WR-1, WR-1.1 DC level control
In-rush current, over-
temperature, output DC, output
over-power, AC mains voltage,
mains fuses
Continuously variable
temperature controlled fan(s)
20A IEC
70-135VAC @110-120VAC,
140-270VAC @220-240VAC
32°F-120°F, (0°C-49°C)
noncondensing
19"W x 3.5"H x 16.1"D
(483 x 89 x 409mm)
CA-502: 15lbs (6.81kg)
CA-504 17.5lbs (7.95kg)
CA-1.02 15.5lbs (7.04kg)
CA-1.04 19.5lbs (8.85kg)
CA-1.52 16lbs (7.26kg)
CA-1.54 20lbs (9.08kg)
21.9"W x 5.43"H x 19.3"D
(556mm x 13.8mm x 489mm)
CA-502 18.5lbs (8.4kg)
CA-504 21.5lbs (9.76kg)
CA-1.02 19.5lbs (8.85kg)
CA-1.04 24.0lbs (10.9kg)
CA-1.52 20.0lbs (9.08kg)
CA-1.54 24lbs (10.9kg)
cTUVus, CE, FCC Class B, RoHS
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ca-502Ca-504Ca-1.02Ca-1.04Ca-1.52Ca-1.54

Table of Contents