Table Of Contents; Introduction; Requirements; Ac Mains - Ashly CA Series Operating Manual

2- and 4-channel
Table of Contents

Advertisement

CA Amplifier • Operating Manual

Table of Contents

1
.................. 4
2
................ 4
....................... 4
.................... 5
...................5
.................... 5
.......................... 6
3
4
......................... 7
.................... 7
.................... 7
...................... 7
5
.........................9
6
7
....... 10-11
8
.................... 12
1

Introduction

Thank you for your purchase of this Ashly CA
power amplifier. This product uses state of the
art, light weight, high power, high efficiency
switching technology developed through
years of design and testing. CA amplifiers are
available in three power levels, designed to
....... 5
meet the most demanding live sound and fixed
installation sound systems in stadiums, arenas,
performance venues, worship spaces and
....... 6
convention centers.
...... 7
1.2
Features
Two or four channel models
.. 7
500W, 1,000W, or 1,500W per channel
models
...... 7
Active power factor correction (PFC)
Low impedance output (to 2 Ohm)
.......... 7
................ 7
Direct 70V or 100V output
.............. 7
....... 8
Extremely efficient and lightweight
........ 8
Neutrik® Combo XLR - 1/4" jack and
............ 8
Euroblock input connectors
........ 8
Euroblock speaker output connectors
.............8
..........8
Front panel soft-power switch, defeatable
.............8
Front panel level controls, fully off = mute,
........8
defeatable
..8
.........8
Front panel LEDs for clip/mute, signal,
...........9
current, temperature, bridge mode, protect,
..............9
and front panel disable
80Hz 2nd order hi-pass filter per channel
............ 9
(on/off)
Clip limiter per channel (on/off)
Input gain settings per channel: 26dB,
32dB, 38dB, or 1.4V
Remote DC level control per channel
Remote standby contact closure, with
polarity setting
Universal 100-240VAC operation, 50-60Hz,
detachable AC connector
Continuously variable cooling fan(s)
Protection: Inrush current limitation, over-
temperature, output short-circuit/over-
power, output DC, mains fuse
Safety/Compliance: cTUVus, CE, FCC Class
B, RoHS
Ashly five year warranty
2

Requirements

Before connecting to AC mains power, make
sure that the mechanical installation, cooling
requirements, wiring, and controls are all set to
the configuration needed for your application.
Failure to do so could result in damage to the
unit or to other components in the system.
2.1

AC Mains

This amplifier will auto-detect AC mains
voltage from 100 to 240VAC, 50-60Hz. For
nominal 120VAC mains, the allowed operating
range is 70-135VAC, with 85VAC required for
start-up. For nominal 240VAC operation the
range is 140-270VAC. Use only the provided
AC cord to connect to AC mains.
All CA models have a fixed, non-defeatable
warm-up delay of two seconds to protect
against excessive in-rush current when first
4