Servo Amplifier Standard Specifications; Mr-Jet-_G-N1 - Mitsubishi Electric MELSERVO-JET MR-JET-G-N1 Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-JET MR-JET-G-N1 Series:
Table of Contents

Advertisement

1.3

Servo amplifier standard specifications

MR-JET-_G-N1

Model: MR-JET-_-N1
Output
Voltage
Rated current [A]
Power supply input
Voltage/Frequency
Rated current [A]
Permissible voltage
fluctuation
Permissible
frequency
fluctuation
Power supply
capacity [kVA]
Inrush current [A]
Interface power supply
Voltage
Current capacity [A]
Control method
Dynamic brake
EtherCAT
Communication
cycle
Communication function
USB
Protective functions
Compliance to standards
CE marking
UL standard
Structure (IP rating)
*2
Close mounting
3-phase power
supply input
1-phase power
supply input
Mass [kg]
*1 This value is applicable when all I/O signals are used. Reducing the number of I/O points decreases the current capacity.
*2 If closely mounting the servo amplifiers, operate them at an ambient temperature of 0 ˚C to 45 ˚C or at 75 % or less of the effective load
ratio.
*3 This current value is applicable when a 3-phase power supply is used.
*4 If using 1-phase 200 V AC to 240 V AC power supply, operate the servo amplifier at 75 % or less of the effective load ratio.
10G
20G
3-phase 0 V AC to 240 V AC
1.3
1.8
3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz
*3
0.9
1.5
3-phase or 1-phase 170 V AC to 264 V AC
Within ±5 %
Refer to "Power supply capacity and generated loss" in the following manual.
MR-JET User's Manual (Hardware)
Refer to "Inrush current at power-on" in the following manual.
MR-JET User's Manual (Hardware)
24 V DC ±10 %
*1
0.3
Sine-wave PWM control, current control method
Built-in
125 μs, 250 μs, 500 μs, 1 ms, 2 ms, 4 ms, 8 ms
Connection to a personal computer or others (MR Configurator2-compatible)
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal), servo motor
overheat protection, encoder error protection, regenerative error protection, undervoltage protection,
instantaneous power failure protection, overspeed protection, and excessive error protection
LVD: EN 61800-5-1, EMC: EN 61800-3
UL 61800-5-1
Natural cooling, open (IP20)
Possible
Possible
0.8
40G
70G
100G
2.8
5.8
6.0
3-phase or 1-phase 200 V
AC to 240 V AC, 50 Hz/60
*4
Hz
2.6
3.8
5.0
3-phase or 1-phase 170 V
AC to 264 V AC
Impossible
1.6
1.3 Servo amplifier standard specifications
200G
300G
11.0
11.0
3-phase 200
V AC to 240
V AC, 50 Hz/
60 Hz
10.5
14.0
3-phase 170
*4
V AC to 264
V AC
Force cooling, open (IP20)
2.1
1 SPECIFICATIONS
9
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents