i) Verify that all three points are still leveled.
j) Hold the leveling nut in place with a 3/4 in. open
end wrench while you secure the inside nut to
the cabinet. Do this for both sides.
Inside nuts
D o not m ove the leveling nut w hen securing
the inside nut to the cabinet.
k) Replace the drive side cabinet cover at this time.
IN F O R M AT IO N
Y ou w ill need the control side cabinet cover
off to connect the electrical pow er.
Page 4 - 10
9
C AU T IO N
F 60 C Operation and Maintenance Manual

4.9 Connecting power

ELECTRICAL
Only a qualified electrician should connect
power to the laminator. You can be severely
shocked, electrocuted or cause a fire if
power is improperly applied.
Tools required
• 1/8 in. allen wrench
• # 2 phillips head screw driver
• Multi meter
a) Ensure the power at the junction box is in the
OFF position.
b) Feed the power cable through the main power
strain relief from the accessory pack, then
through the hole provided below the circuit
breaker on/ off.
Line Term inal B lock
© April 2001 General Binding Corporation
S H O C K
S train relief
P ower cable