Overview

The left side of the mix manifold is intended for the
major volume material, or the higher viscosity material if
using a 1:1 volume mix. This side is referred to through-
out the manual as the resin side or "A" side. The right
side is referred to as the hardener side or "B" side.
See F
. 2 to view flow of A and B material inside the
IG
XM PFP Mix Manifold.
The resin and hardener enter the manifold through the
manifold inlet ports. The A material flows through the
manifold to the material outlet port. The injector tube
creates a hollow stream of A material for the B material
to combine with once the hardener exits the injector (P).
The resin and hardener materials enter the mix manifold
outlet (R) before the materials enter the first length of
integrator fluid hose (L). The materials then pass
through the mixer assembly (S) where they are thor-
oughly mixed. Then they pass through a length of mix
hose (T1) where the continue to be lightly mixed before
entering the fluid whip hose (T2) then the gun (U).
SECTION A-A
Hardener
Resin
Combined Material
F
. 2: Cutaway View
IG
3A2988C
Top View
Follow these recommendations for setup (see F
page 6):
Use at least a 1/2 in. (12 mm) x 2 ft (0.6 m) integra-
tor hose (L) connected to the mix manifold outlet
Use at least 12 elements in the static mixer after the
integration hose and before the mix hose (T1).
Use at least a 1/2 in. (12 mm) x 10 ft (3.0 m) mix
hose (T1) after the static mixer and before the spray
gun.