Operation
8. Cycle the solvent flush ball valves on and off inde-
pendently several times to be sure both sides are
thoroughly flushed. Continue flushing until clean sol-
vent dispenses.
9. Turn off solvent pump air supply.
10. Hold the metal part of the gun firmly to a grounded
metal pail with lid in place. Trigger gun until all fluid
pressure is relieved.
11. Engage trigger lock.
12. Close solvent inlet valves.
12
ti19269a
ti20095a

Dispensing and Spraying

1. Close solvent inlet valves.
2. Open mix manifold inlet ball valves.
3. Ensure sprayer is in "spray" mode and push the
green START button.
4. Disengage spray gun trigger lock.
5. Hold the metal part of the gun firmly to a grounded
metal pail with a lid to avoid splashing. Trigger the
gun until mixed coating material is evident and
flushing fluid is gone.
6. Proceed to spraying.
ti20095a
ti20128a
ti19265a2