Supported Fiber Optic Cables; Ingress Protection - Siemens RUGGEDCOM RS969 Installation Manual

Hide thumbs Also See for RUGGEDCOM RS969:
Table of Contents

Advertisement

Chapter 1
Introduction
Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across
distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground
fault conditions.
CONTENTS
Section 1.4.1, "Supported Fiber Optic Cables"
Section 1.4.1

Supported Fiber Optic Cables

The following fiber optic cable types are supported under the stated conditions.
Cable Type
OM1 (62.5/125)
OM2 (50/125)
a
OM3 (50/125)
a
OM4 (50/125)
a
Laser optimized.
Section 1.5

Ingress Protection

IEC International Standard 60529 (Edition 2.1: 2001-02) is a "classification of degrees of protection provided
by enclosures as a system for specifying the enclosures of electrical equipment on the basis of the degree of
protection provided by the enclosure." These ratings are determined by specific tests.
The RUGGEDCOM RS969 Industrial Ethernet Switch is manufactured and tested to IP67 standards. With an IP67
rating a product will be "dust tight" and remain completely sealed when immersed in water to a depth of 1 meter
for 1 hour (IEC 60529).
These caps completely seal off unused ports on the IP67 Industrial Ethernet Switch. It has an IP67 rated seal that
keeps out all contaminants like dirt, oil, and water.
6
Modal Bandwidth
Wavelength (nm)
(MHz·km)
850
1300
850
1300
850
1300
850
1300
100Base-FX
200
500
2000
500
500
2000
1500
500
2000
3500
500
2000
RUGGEDCOM RS969
Installation Guide
Distance (m)
1000Base-SX
10GBase-SR
275
33
550
82
550
300
550
400
Supported Fiber Optic Cables