Fan Tray Leds - Cisco ASR 907 Hardware Installation Manual

Hide thumbs Also See for ASR 907:
Table of Contents

Advertisement

Fan Tray LEDs

Table 41: Power Supply LEDs
LED
Input OK
Output
Fail
Fan Tray LEDs
The table below summarizes the fan tray LEDs.
Table 42: Fan Tray LEDs
LED
Status (TEMP)
Fan (FAN)
Minor (MIN)
Major (MAJ)
Critical
(CRIT)
Cisco ASR 907 Router Hardware Installation Guide
190
Color/State
Description
Off
No Input Voltage
Amber
Input voltage out of range
Green
Input voltage within acceptable operating range
Disabled/Forced Shut down/No input power
Off
Red
Power supply fault (internal failure such as over temperature)
Green
Operational
Blinking
Output ORING FET Failed
Red
Color/State
Description
Off
Disabled/power down
Amber
Over temperature
Green
OK
Green
Fan rotation in range
Amber
Fan fault
Red
Two or more fan faults
Off
No minor alarm
Amber
Minor alarm
Off
No major alarm
Red
Major alarm
Off
No critical alarm
Red
Critical alarm (defaults to ON upon RSP reset)
Troubleshooting