THERMAL
SET-UP MENU
TRIM
Recommended Processes and
Equipment
RECOMMENDED PROCESSES
GMAW, GMAW-Pulse, GMAW-STT
FCAW
SMAW
GTAW
CAG
PROCESS LIMITATIONS
Processes must be within the duty cycle and rating
of the wire feeder.
EQUIPMENT LIMITATIONS
The Power Feed 84 does not operate with LincNet
Power Sources.
The power source may require a software update.
If the Power Feed 84 has contactors or a gouging kit
installed, the power source software may require
updated.
Does not include weld cables
Operates on 40 VDC input
The user interface may be located a maximum of
60m away from the wire drive.
Must use newer gun adapter kits. Not compatible
with K1500-1, K1500-2, K1500-3, K1500-4 K1500-5
and K489-7 gun adapter kits.
A remote control/foot amptrol and a push-pull gun
may not be connected to the Power Feed 84 single
simultaneously.
Power Feed 84 user interfaces are not compatible
with Power Feed 10M wire drives.
Power Feed 84 wire drives are not compatible with
Power Feed 10M user interfaces.
The Power Feed 84 with contactors or gouging kit
may not be connected to a system with a robotic
wire drive.
With the Power Feed 84, only one USB port may
present anywhere in the system.
RECOMMENDED POWER SOURCES
Power Wave 355M, 455M
Power Wave 455M/STT
Power Wave 655R
Power Wave S350
Power Wave S500
Power Wave S700
Power Wave R350, R500
Power Wave i400
Speedtec 405, 505
Flextec 350x, 500, 650x
English
User Interface Layout
(See Figure #35)
1.
Wire feed speed/amps
2.
Volt/trim
3.
Thermal
4.
Set-up menu
5.
2-step/4-step trigger
6.
Arc start parameters
7.
Arc end parameters
8.
Memory buttons
9.
Wire drive select
10. Dual procedure
11. Arc control
12. Weld mode menu
13. Shielding gas
Wire Feed Speed/Amps Display and
Knob
(see Figre #36)
The left display and knob are used to adjust either wire
feed speed or amperage, depending upon the process
selected.
While welding, the amps LED lights when amperage is
displayed and the wire feed speed LED lights when WFS
is displayed.
16
Figure #35
Figure #36