Model 750 Specifications - Taylor 336 Service Manual

Table of Contents

Advertisement

Model 750 Specifications

Freezing Cylinder
One, 3.4 quart (3.2 liter) volume.
Mix Hopper
One, 20 quart (18.9 liter) capacity.
Beater Motor
One, 1.5hp.
Refrigeration Unit
One, approximately 4,900 btu/hr compressor. Refrigerant
R404A.
One independent (SHR) compressor, approximately 400
btu/hr. Refrigerant R134a. (BTU's may vary based on
compressor used.)
Electrical
Electrical
208-230/60/1 Air
208-230/60/1 Water
208-230/60/3 Air
208-230/60/3 Water
This unit is manufactured in other electrical
characteristics. Refer to the Distributor Data Book for
One dedicated connection.
Maximum
Minimum
Fuse Size
Circuit Ampacity
20
18
20
18
15
12
15
12
availability. (For exact electrical information, always refer
to the data label of the unit.)
Air Cooled
Clearance: 6" (15.2 cm.) on both sides. It is
recommended to place the back of the unit against a
wall. This will assure proper air flow across condensers
to obtain optimum performance.
Water Cooled
Water inlet and drain connections 3/8" FPT.
Dimensions
Width: 18-7/16" (46.8cm.)
Depth: 31-3/16" (79.2cm.)
Height: 37-7/8" (96.2 cm.)
Counter Clearance: 4-1/2" (10.8 cm.) mounted on
standard legs.
Approximate Weights
Net: 360 Ibs. (163.3 kgs.) Crated: 410 Ibs. (186.0 kgs.),
29.1 cu. ft. (.81 cu. m.)
Availability and specifications are subject to change
without notice.
This unit is designed and constructed to meet stringent
safety and sanitation requirements for NSF and UL.