Model 339 Specifications - Taylor 336 Service Manual

Table of Contents

Advertisement

Model 339 Specifications

Freezing Cylinder
Two, 2.8 quart (2.7 liter) volume.
Mix Hopper
Two, 20 quart (18.9 liter) capacity.
Beater Motor
Two, 1.0 hp.
Refrigeration Unit
Two, approximately 6,000 btu/hr compressors.
Refrigerant R404A.
One independent (SHR) compressor, approximately
400 btu/hr. Refrigerant R134a.
(BTU's may vary based on compressor used.)
Electrical
Electrical
208-230/60/1 Air
208-230/60/1 Water
208-230/60/3 Air
208-230/60/3 Water
This unit is manufactured in other electrical
characteristics. Refer to the Distributor Data Book for
Two dedicated connections.
Maximum
Minimum Circuit
Fuse Size
Ampacity
Left
Right
Left
25
20
19
20
20
16
20
15
16
20
15
14
availability. (For exact electrical information, always refer
to the data label of the unit.)
Air Cooled
Clearance: 3" (7.6 cm.) around all sides. A deflector has
been added to underside preventing recirculation of
warm air. This will assure proper air flow across
condensers to obtain optimum performance.
Water Cooled
Water inlet and drain connections under side of base 1/2"
FPT.
Dimensions
Width: 26-7/16" (67.2 cm.)
Depth: 33" (83.8 cm.)
Height: 59-7/8" (152.1 cm.)
Floor Clearance: 7-1/2" (19.1 cm.) mounted on
standard casters.
Approximate Weights
Net: 608 Ibs. (275.8 kgs.) Crated: 698 Ibs. (316.6 kgs.),
48.1 cu. ft. (1.3 cu. m.)
Availability and specifications are subject to change
without notice.
This unit is designed and constructed to meet stringent
Right
safety and sanitation requirements for NSF and UL