S/W Download - Panasonic External Presentation unit 1728 Technical Description

Hide thumbs Also See for External Presentation unit 1728:
Table of Contents

Advertisement

Panasonic Electric Works Fire & Security Technology Europe AB
MEW00290 Rev: 1
11.2
Technical Description External Presentation unit 1728
5 The ext. Presentation unit will restart, i.e. the buzzer will sound
for approx. two seconds and the unit will return to normal
operation.

S/W download

Each ext. Presentation unit is equipped with an RS232 interface
("J2"), which makes it possible to connect a PC and carry out the
downloading directly in the ext. Presentation unit respectively.
1. Prepare the PC and start Win512 / Win128. In Win512 select
the ext. Presentation unit icon and click the right mouse
button.
In win128, in menu "Tools" select "Download
FBP/ EPU / AAU Software". Select "Download program"
and select the SW file to be downloaded, i.e.
DU_version.BIN (where "version" is the valid program
version, e.g. 11=program version 1.1). Check / set the port
and baud rate. See also the Win512 / Win128 help.
2. Connect the PC to the ext. Presentation unit ("J2").
3. Put the jumpers "JP3" and "JP4" in position "A".
4. Shunt the jumper "JP2" (BOOT).
5. Put the ext. Presentation unit in "bootstrap" mode, i.e. shunt the
jumper "JP1" (RESET) momentarily.
sound.
6. Start the downloading. The buzzer will be silenced.
7. When the download is ready, open the jumper "JP2" (BOOT).
8. Put the jumpers "JP3" and "JP4" in position "B".
9. Do a restart, i.e. shunt the jumper "JP1" (RESET) momen-
tarily. The buzzer will sound for approx. two seconds and
the ext. Presentation unit will return to normal operation.
10. Regarding fault messages, see chapter "Restart", page 18.
22
The buzzer will

Advertisement