Set Screw
#9900824
Crosshead
#1063000
MAINTENANCE ALL MODELS CONTINUED
CD
Adjusting
ADJUSTMENT
OF
GUIDES
The Guide Plate and Crosshead can be
adjusted if they become noisy or freeze. If
the Guides are scored or marred it will be
necessary to replace them. To adjust the
Guides, remove the Sharpener Housing
Assembly. Remove the Connecting Rod (#1 in
Fig. A) by loosening the two Connecting Rod
screws (#2 in Fig. A). Loosen two screws
#9900824 (#1 in Fig. B) and retighten to a
snug fit, to keep the Guides from cocking
while adjusting. Loosen Locknut #1062200
(#2 in Fig. B) and slowly tu rn adjusting set
screws #9901810 in direction needed for
more or less play in the Guides. After getting
proper fit (the Crosshead [#4 in Fig. B] should
be free but with no side play) tighten screws
#9900824. Tighten Locknut #1062200 while
holding Slotted Set screw with screw driver to
keep from turning. Replace the Connecting
Rod, making sure that the rod is tight against
the Crosshead Wear Plate (#5 in Fig. B) with
the Wrist Pin drawn forward to apply pressure
against the Spring Washer located between
Crosshead and head of Wrist Pin. When
properly positioned, tighten the Connecting
Rod screws (#2 in Fig. A)
Additional adjusting of Guide Plate is done
while machine is running. Adjust Guide inward
until machine runs with minimum amount of
noise, then back out slightly and lock in place.
When new Guides are installed this adjust­
ment will have to be made several times until
the Guides have developed a shiny black
glaze on their surface. When proper adjustment
is made, tighten the Locking screws (#1 in Fig. B).
®
Locknut
#1062200
CD
Loosen
screws
before
adjusting
CD