IBM Power System 9009-42A Manual
IBM Power System 9009-42A Manual

IBM Power System 9009-42A Manual

Pcie adapter placement
Hide thumbs Also See for Power System 9009-42A:

Advertisement

Power Systems
PCIe adapter placement for the
9009-41A, 9009-42A, or 9223-42H
IBM

Advertisement

Table of Contents
loading

Summary of Contents for IBM Power System 9009-42A

  • Page 1 Power Systems PCIe adapter placement for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 2 Note Before using this information and the product it supports, read the information in “Safety notices” on page v, “Notices” on page 17, the IBM Systems Safety Notices manual, G229-9054, and the IBM Environmental Notices and User Guide, Z125–5823. ®...
  • Page 3: Table Of Contents

    PCIe adapter placement rules and slot priorities for the EMX0 PCIe Gen3 I/O expansion drawer..8 Related procedures for PCIe adapter placement..................15 Finding the current system configuration in IBM i................15 Notices........................17 Accessibility features for IBM Power Systems servers................18 Privacy policy considerations ........................
  • Page 5: Safety Notices

    Das Produkt ist nicht für den Einsatz an Bildschirmarbeitsplätzen im Sinne § 2 der Bildschirmarbeitsverordnung geeignet. Laser safety information IBM servers can use I/O cards or features that are fiber-optic based and that utilize lasers or LEDs. Laser compliance IBM servers may be installed inside or outside of an IT equipment rack.
  • Page 6 – For racks with a DC power distribution panel (PDP), connect the customer’s DC power source to the PDP. Ensure that the proper polarity is used when attaching the DC power and DC power return wiring. • Connect any equipment that will be attached to this product to properly wired outlets. •...
  • Page 7 • Rack-mounted devices are not to be used as shelves or work spaces. Do not place objects on top of rack-mounted devices. In addition, do not lean on rack mounted devices and do not use them to stabilize your body position (for example, when working from a ladder). •...
  • Page 8 – Remove all devices in the 32U position (compliance ID RACK-001 or 22U (compliance ID RR001) and above. – Ensure that the heaviest devices are installed in the bottom of the rack cabinet. – Ensure that there are little-to-no empty U-levels between devices installed in the rack cabinet below the 32U (compliance ID RACK-001 or 22U (compliance ID RR001) level, unless the received configuration specifically allowed it.
  • Page 9 DANGER: Rack-mounted devices are not to be used as shelves or work spaces. Do not place objects on top of rack-mounted devices. In addition, do not lean on rack-mounted devices and do not use them to stabilize your body position (for example, when working from a ladder). (L002) (L003) Safety notices ix...
  • Page 10 DANGER: Multiple power cords. The product might be equipped with multiple AC power cords or multiple DC power cables. To remove all hazardous voltages, disconnect all power cords and power cables. (L003) (L007) CAUTION: A hot surface nearby. (L007) (L008) CAUTION: Hazardous moving parts nearby.
  • Page 11 Exchange only with the IBM-approved part. Recycle or discard the battery as instructed by local regulations. In the United States, IBM has a process for the collection of this battery. For information, call 1-800-426-4333. Have the IBM part number for the battery unit available when you call.
  • Page 12 Freewheeling will cause uneven cable wrapping around winch drum, damage cable, and may cause serious injury. • This TOOL must be maintained correctly for IBM Service personnel to use it. IBM shall inspect condition and verify maintenance history before operation. Personnel reserve the right not to use TOOL if inadequate.
  • Page 13 The dc-powered system employs an isolated DC return (DC-I) design. The DC battery return terminal shall not be connected to the chassis or frame ground. The dc-powered system is intended to be installed in a common bonding network (CBN) as described in GR-1089-CORE.
  • Page 14 xiv Power Systems: PCIe adapter placement for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 15: Pcie Adapter Placement

    One slot (P1-C9) One slot (P1-C9) Three slots (P1-C3 PCIe4 x16 Full-height, half- P1-C4, P1-C9) length One slot (P1-C8) One slot (P1-C8) Two slots (P1-C2, PCIe4 x8 with x16 Full-height, half- P1-C8) connector length © Copyright IBM Corp. 2018, 2019...
  • Page 16 Two PCIe3 switches in the system backplane provide PCIe3 buses from the system processor modules that provide connectivity to the following features: Note: PCIe3 switch 1 and switch 2 provide PCIe buses from processor module SCM0. • PCIe slots • PCIe local area network (LAN) controller •...
  • Page 17 Figure 1. Rear view of a rack-mounted 9009-41A, 9009-42A, or 9223-42H system with PCIe slots location codes Table 4. PCIe slot locations and descriptions for system Location Description Processor Adapter Slot capabilities Slot availability code module size CAPI SR-IOV 32-bit I/O adapter I/O adapter 9009-41A,...
  • Page 18 Table 4. PCIe slot locations and descriptions for system (continued) Location Description Processor Adapter Slot capabilities Slot availability code module size CAPI SR-IOV 32-bit I/O adapter I/O adapter 9009-41A, 9009-42A dynamic enlarged enlarged 9009-42A, direct capacity capacity 9223-42H memory enablemen enablemen 9223-42H (two...
  • Page 19 PCI adapter information by feature type for the 9008-22L, 9009-22A, 9009-41A, 9009-42A, 9040-MR9, 9080-M9S, 9223-22H, 9223-42H system and the EMX0 PCIe3 expansion drawer (http://www.ibm.com/support/knowledgecenter/POWER9/p9hcd/p9hcd_pcibyfeature.htm). The 9009-42A and 9223-42H systems can have one or two system processor modules. The PCIe slot configuration in the 9009-42A and 9223-42H systems with a single processor module is the same as in the 9009-41A system.
  • Page 20 Table 5. PCIe adapter slot priorities and maximum adapters supported in the 9009-41A, 9009-42A, or 9223-42H (continued) Feature Description 9009-41A, 9009-42A, or 9223-42H 9009-42A or 9223-42H code (one processor) (two processors) Slot priorities Maximum number Slot priorities Maximum number of adapters of adapters supported supported...
  • Page 21 Table 5. PCIe adapter slot priorities and maximum adapters supported in the 9009-41A, 9009-42A, or 9223-42H (continued) Feature Description 9009-41A, 9009-42A, or 9223-42H 9009-42A or 9223-42H code (one processor) (two processors) Slot priorities Maximum number Slot priorities Maximum number of adapters of adapters supported supported...
  • Page 22: Pcie Adapter Placement Rules And Slot Priorities For The Emx0 Pcie Gen3 I/O Expansion Drawer

    PCIe adapter placement rules and slot priorities for the EMX0 PCIe Gen3 I/O expansion drawer Find information about the placement rules and slot priorities for the Peripheral Component Interconnect Express (PCIe) adapters that are supported for the EMX0 PCIe Gen3 I/O expansion drawer (EMX0 PCIe3 expansion drawer).
  • Page 23 Note: The left I/O module bay is configured with the first PCIe3 6-slot fanout module slot location codes P1- C1 through P1-C6. The right I/O module bay is configured with the second PCIe3 6-slot fanout module slot location codes P2-C1 through P2-C6. Figure 2.
  • Page 24 Table 6. PCIe slot locations and descriptions for the EMX0 PCIe3 expansion drawer (continued) Slot capabilities SR-IOV Dynamic direct I/O adapter memory access enlarged capacity Location code Description (DMA) window enablement order P2-C5 PCIe3 x8 P2-C6 PCIe3 x8 Slots P1-C1 and P2-C1 inherit the I/O Adapter Enlarged Capacity attribute from the slot in the system that connects to the EMX0 PCIe3 expansion drawer.
  • Page 25 Feature code Description EMX0 PCIe3 expansion drawer Slot priorities Maximum number of adapters supported ® Linux IBM i 2893 or 2894 PCIe 2-line WAN with P1-C6, P2-C6 modem (FC 2893, 2894, EN13, EN14; CCIN 576C); Part number: 44V5323 5729 PCIe2 FH 4-port 8 Gb Fibre P1-C1, P2-C1, P1-C4, P2- Channel adapter (FC 5729;...
  • Page 26 Description EMX0 PCIe3 expansion drawer Slot priorities Maximum number of adapters supported ® Linux IBM i EC2S PCIe3 2-port 10 Gb NIC & P1-C2, P2-C2, P1-C5, P2- RoCE SR/Cu adapter (FC EC2R and EC2S; CCIN 58FA); Adapter part number: 01FT759...
  • Page 27 Description EMX0 PCIe3 expansion drawer Slot priorities Maximum number of adapters supported ® Linux IBM i EJ1P PCIe1 SAS Tape/DVD dual- P1-C2, P2-C2, P1-C5, P2- port 3 Gb x8 adapter (FC C5, P1-C3, P2-C3, P1-C6 EJ1N and EJ1P; CCIN P2-C6, P1-C1, P2-C1, P1- 57B3);...
  • Page 28 Description EMX0 PCIe3 expansion drawer Slot priorities Maximum number of adapters supported ® Linux IBM i EN0K PCIe3 4-port (10 Gb FCoE P1-C1, P2-C1, P1-C4, P2- 6 (EL57 - and 1 GbE) copper and C4, P1-C2, P2-C2, P1-C3, RJ45 adapter (FC EL3C, P2-C3, P1-C5, P2-C5, P1- EL57, EN0K, and EN0L;...
  • Page 29: Related Procedures For Pcie Adapter Placement

    About this task To find the current system configuration, start an IBM i session and sign on. If you have more than one system, start a session on the system that is being upgraded and for which you have service tools authority.
  • Page 30 8. Look for the PCI adapter location codes in the Location column. 9. Write down the Type-Model number for each PCI adapter location. Some adapters can show multiple, virtual ports. It is not necessary to write down these virtual locations. 10.
  • Page 31: Notices

    Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead.
  • Page 32: Accessibility Features For Ibm Power Systems Servers

    This product uses standard navigation keys. Interface information The IBM Power Systems servers user interfaces do not have content that flashes 2 - 55 times per second. The IBM Power Systems servers web user interface relies on cascading style sheets to render content properly and to provide a usable experience.
  • Page 33: Privacy Policy Considerations

    Contact the vendor for accessibility information about its products. Related accessibility information In addition to standard IBM help desk and support websites, IBM has a TTY telephone service for use by deaf or hard of hearing customers to access sales and support services:...
  • Page 34: Class A Notices

    Class A Notices The following Class A statements apply to the IBM servers that contain the POWER9 processor and its features unless designated as electromagnetic compatibility (EMC) Class B in the feature information. Federal Communications Commission (FCC) Statement Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 35 Japan Electronics and Information Technology Industries Association Statement This statement explains the Japan JIS C 61000-3-2 product wattage compliance. This statement explains the Japan Electronics and Information Technology Industries Association (JEITA) statement for products less than or equal to 20 A per phase. This statement explains the JEITA statement for products greater than 20 A, single phase.
  • Page 36 Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
  • Page 37: Class B Notices

    Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Proper cables and connectors are available from IBM-authorized dealers. IBM is not responsible for any radio or television interference caused by unauthorized changes or modifications to this equipment.
  • Page 38 Tel: +49 800 225 5426 email: halloibm@de.ibm.com VCCI Statement - Japan Japan Electronics and Information Technology Industries Association Statement This statement explains the Japan JIS C 61000-3-2 product wattage compliance. This statement explains the Japan Electronics and Information Technology Industries Association (JEITA) statement for products less than or equal to 20 A per phase.
  • Page 39: Terms And Conditions

    Permissions for the use of these publications are granted subject to the following terms and conditions. Applicability: These terms and conditions are in addition to any terms of use for the IBM website. Personal Use: You may reproduce these publications for your personal, noncommercial use provided that all proprietary notices are preserved.
  • Page 40 IBM reserves the right to withdraw the permissions granted herein whenever, in its discretion, the use of the publications is detrimental to its interest or, as determined by IBM, the above instructions are not being properly followed.
  • Page 42 IBM®...

This manual is also suitable for:

Power system 9009-41aPower system 9223-42h

Table of Contents