Drive Assembly Removal And Installation - Pentair INTELLIFLO Installation And User Manual

Variable speed pump
Table of Contents

Advertisement

1. Be sure all electrical breakers and switches are turned
off before installing the drive.
2. Be sure that the gasket between the drive and motor
is in place. It is critical in keeping moisture out of the
drive and motor. Replace the gasket if damaged. Do
not reassemble with a damaged or missing gasket.
3. Verify that the three (3) orange motor post caps are
in position before placing the drive on the motor
assembly.
4. Align the drive assembly with the motor adapter and
seat the drive on the motor assembly.
5. Secure and tighten the drive assembly with the three
(3) Phillips head screws.
6. Plug the keypad cover back into the drive.
7. Place the keypad cover in the desired orientation
on the drive and reattach the four (4) screws in the
corners of the drive.
Ensure that the keypad cable is not being
pinched between the drive and keypad cover.
Drive Assembly and Removal
INTELLIFLO
Variable Speed Pump Installation and User's Guide
®
23