Download Print this page
Pentair INTELLIFLO Installation Manual

Pentair INTELLIFLO Installation Manual

Variable speed pump drive

Advertisement

Quick Links

INTELLIFLO
VARIABLE SPEED PUMP DRIVE
ASSEMBLY REPLACEMENT KIT
INSTALLATION GUIDE
Kit Contents
1. Keypad Assembly — (P/N 357527Z [Almond]
or P/N 358527Z [Black]), (Qty. 1)
2. IntelliFlo or IntelliPro Pump Drive Assembly
— (Qty. 1)
3. Screw 10-24 X 3¼ inch PH MS 18-8 S/S
— (P/N 356871), (Qty. 3)
4. Motor Post Cap — (P/N 350142), (Qty. 3)
5. Drive Gasket — (P/N 350108), (Qty. 1)
experience a build up of vapor pressure and may contain scalding hot water. Opening the pump may
cause serious personal injury. In order to avoid the possibility of personal injury, make sure the suction and
discharge valves are open and strainer pot temperature is cool to touch, then open with extreme caution.
IMPORTANT NOTE FOR INTELLIFLO AND INTELLIPRO VS+SVRS DRIVE KITS:
The replacement IntelliFlo or IntelliPro VS+SVRS drive assembly must ONLY be used on
the original IntelliFlo or IntelliPro VS+SVRS pump. This replacement SVRS drive assembly
is NOT to be used with a non-SVRS pump. The original SVRS pump serial number is
referenced in the PO# of this shipment or is included in the body of the packing list. If the
referenced serial number does not match the serial number of the pump being serviced,
please call Pentair Technical Support at 1-800-831-7133.
AND INTELLIPRO
®
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION:
PUMPS REQUIRE HIGH VOLTAGE WHICH CAN SHOCK, BURN, OR CAUSE
DEATH. BEFORE WORKING ON PUMP! Always disconnect power to the
pool pump at the circuit breaker from the pump before servicing the pump.
Failure to do so could result in death or serious injury to service person,
pool users or others due to electric shock.
Read all servicing instructions before working on the pump.
DO NOT open the strainer pot if pump fails to prime or if pump has been operating
without water in the strainer pot. Pumps operated in these circumstances may
1
2
®
3
4
5

Advertisement

loading

Summary of Contents for Pentair INTELLIFLO

  • Page 1 IMPORTANT NOTE FOR INTELLIFLO AND INTELLIPRO VS+SVRS DRIVE KITS: The replacement IntelliFlo or IntelliPro VS+SVRS drive assembly must ONLY be used on the original IntelliFlo or IntelliPro VS+SVRS pump. This replacement SVRS drive assembly is NOT to be used with a non-SVRS pump.
  • Page 2 Introduction The IntelliFlo Variable Speed Pump Drive Assembly Replacement Kit contains ® everything you need to replace the existing drive assembly on the IntelliFlo Variable Speed Pump. Drive Assembly Removal AVOID TOUCHING ELECTRICAL CONTACT ON UNDERSIDE OF DRIVE ASSEMBLY. THE CONTACTS MAY BE ENERGIZED BY INTERNAL CAPACITORS FOR SEVERAL MINUTES AFTER EXTERNAL POWER IS REMOVED.
  • Page 3 Drive Assembly Installation Note: The gasket between the drive and motor is critical in keeping moisture out of the drive and motor. DO NOT reassemble with a damaged or missing gasket. The manufacturer recommends replacing the existing gasket with the one supplied in this kit before installing the replacement drive assembly.
  • Page 4 1620 HAWKINS AVE., SANFORD, NC 27330 • (919) 566-8000 10951 WEST LOS ANGELES AVE., MOORPARK, CA 93021 • (805) 553-5000 WWW.PENTAIRPOOL.COM All Pentair trademarks and logos are owned by Pentair or one of its global affiliates. IntelliFlo , IntelliPro ®...

This manual is also suitable for:

Intellipro