Drive Assembly Removal and Installation

FIRE and BURN HAZARD - The pump motor may run at a high temperatures. To reduce the risk of fire, do not allow leaves, debris,
or foreign matter to collect around the pump motor. To avoid burns when handling the motor, shut off the motor and allow it to cool
for 20 minutes before servicing. The pump provides an automatic internal cutoff switch to protect the motor from heat damage during operation.
To avoid electrical hazard, do not remove the four tamper proof screws from the motor assembly.
To remove the drive and control panel from the
motor assembly:
1. Ensure all electrical breakers and switches are
turned off before removing the control panel.
2. Disconnect the RS-485 communication cable
from the pump (if connected).
3. Remove the four (4) Phillips-head screws from the
outer corners of the keypad.
4. Unplug the keypad from the drive and set it to the
side.
5. Remove the three (3) Phillips-head screws,
located inside the drive, that anchor the drive to
the motor.
6. Lift up the drive assembly and remove it from
the motor adapter located on top of the motor
assembly.
Note: Be careful not to remove the gasket
between the drive and motor, it is critical in
keeping moisture out of the drive and motor.
Replace the gasket if damaged. Do not
reassemble with a damaged or missing gasket.
XF
®
INTELLIFLO
and INTELLIPRO
Keypad
Assembly
Keypad
Screws (4x)
#10-24 X 2"
Phillips Head
Screws, Drive to
Motor (3x)
Drive to
Motor Gasket
Motor Post
Caps (3x)
Drive
Connector
Drive Assembly and Removal
XF
®
VSF Variable Speed and Flow Pump Installation and User' s Guide
To install the drive assembly onto the motor
assembly:
1. Ensure all electrical breakers and switches are
turned off before installing the drive.
2. Ensure that the gasket between the drive
and motor is in place. It is critical in keeping
moisture out of the drive and motor. Replace
the gasket if damaged. Do not reassemble with
a damaged or missing gasket.
3. Verify that the three (3) orange motor post
caps are in position before placing the drive on
the motor assembly.
4. Align the drive assembly with the motor
adapter and seat the drive on the motor
assembly.
5. Secure and tighten the drive assembly with the
three (3) Phillips-head screws.
6. Plug the keypad back into the drive.
7. Place the keypad in the desired orientation on
the drive and reattach the four (4) screws in
the corners of the drive.
Note: Ensure that the keypad cable is not
being pinched between the drive and keypad.