Sc740-03; Overcurrent Protection Device Error 1 (Cover Interposer Tray) - Ricoh Pro 8300S Troubleshooting Manual

Hide thumbs Also See for Pro 8300S:
Table of Contents

Advertisement

1.SC Codes
Error Condition
The cover interposer tray cannot communicate with the downstream device.
Major Cause
Power of downstream unit is not turned on
Interface cable (between the cover interposer tray and downstream device) is disconnected or
damaged/
Cover interposer tray PCB is defective.
Downstream device PCB is defective.
Solution
1.
Check that the downstream device is turned ON.
2.
Check that the downstream device power cord is connected.
3.
Check that the interface cable between the downstream unit and the cover interposer tray is
connected correctly.
4.
Replace the interface cable.
5.
Replace the downstream device PCB.
6.
Replace the cover interposer tray PCB.

SC740-03

Error Name

Overcurrent Protection Device Error 1 (Cover Interposer Tray)

Pattern
D
Error Condition
The fuse on the PCB blew,
Major Cause
Power of downstream unit is not turned on.
Harness is damaged.
Actuator is defective.
Main controller board is defective,
Solution
1.
Replace the actuator.
2.
Replace the harness.
3.
Replace the main controller board.
302

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pro 8310sPro 8320sPro 8310Pro 8320

Table of Contents