System
Available for
WS4 series

ESC+W1 IP Address

IP Address
ESC
Hex code
<1B>
Default setting
a~a=000000000000
When printer is powered off
Persistence of the
Validity in a job
command
Validity after a job
[Function]
Sets IP address.
[Format]
<W1>a~a
●Parameter
a~a
[IP address]
[Coding Example]
<A>
<W1>123220000040
<Z>
[Notes]
1. Place this command between start code<A> and stop code<Z>.
2. This command may not be used in combination with other commands.
3. Setting can be printed on the factory test print.
4. The set parameter will become valid after rebooting.
5. Default setting of IP address is as follows:
IP address
W1
<57>
<31>
16
16
16
= 12 digit fixed
000000000000
Parameter
a~a
Set Parameter will be retained
Becomes invalid after execution
Becomes invalid after the job