Sequemnce
Item
11
Flash check
12
LCD dust/defect
Playback
check
13
Battery low check
Movie
14
Current
Auto mode
consumption
LCD-ON
check
15
Shipping
inspection
Mode
Preparations for adjustment
(measurement points, subject, other)
(1) Set the flash mode to
AUTO.
(2) Check that the flash pops
up when a picture is taken.
(1) Insert a standard xD-
Picture card.
(2) Play back a completely
black image.
(3) Play back a completely
white (75%) image.
(4) Change the setting with
the EVF/LCD button.
(1) Connect the power supply
jig to the DC_IN terminal.
(2) Set the power supply
voltage.
(3) Set the Mode dial to Movie
or Camera mode and turn
the camera on.
(4) Set the pre-end voltage.
(5) Set the end voltage.
(1) Connect the power supply
jig to the DC_IN terminal.
(2) Set the power supply
voltage.
(3) Set the Mode dial to AUTO
and turn the camera on.
(4) After the LCD live image
appears, check the current
consumption.
(1) Mode dial
(2) SETUP frame No.
(3) Battery and cards not
inserted
(4) Battery cover
(5) EVF diopter adjustment
dial
(6) Focus mode SW lock lever
5. Inspection
Method of adjustment
(VRs, waveforms, required values)
(1) Press the 4-way button
(right) and check that
"AUTO" appears on the
LCD monitor.
(2) Check that there are no
noticeable dust flecks or
stains (bright spots) on the
screen.
(3) Check that there are no
noticeable dust flecks or
stains (smears, flashing
points, etc.) on the screen.
(4) Play the above 2 frames
and perform the same
checks.
(2) 5.00±0.05 V
(3) Check that the camera
starts up normally.
(4) 4.40±0.02 V
Check that the battery low
warning appears.
(5) 4.00±0.02 V
Check that the camera
turns off.
(2) 5.00±0.05 V
(4) 450 mA or less
(Stable state -> IRIS/
FOCUS does not operate)
(1) AUTO
(2) New: The default SETUP
frame No. setting is
"Continuous", but to clear
the number of frames in
the frame number memory
to zero, you should always
change the setting to
"New" before turning the
camera off.
(4) Closed
(5) Center position indicator
located close to the center.
(6) Locked
Measuring
Measurement points
equipment and jigs
(VRs, positions)
ZJ00885-100