18.

PARAMETER TABLE

Par.
Description
P1
Temperature measurement unit 0 = °C 1 = °F
P2
Pressure measurement unit 0= bar 1=Atm 2=kPa
P3
Volume measurement unit 0 = liters, 1 = gallons
P4
Number of groups present
P5
User interface language
Cup-warmer operation enabling
P6
0 = disabled.
1 = enabled.
Presence of service boiler pressure transducer:
P7
0 = Absent.
1 = Present.
Enabling hot water dispensing together with the
coffee.
P8
0 = disabled.
1 = enabled.
Enable long coffee selections.
P9
0 = disabled.
1 = enabled.
Enable pre-infusion.
P10
0 = disabled.
1 = enabled.
Autosteamer activation
0 = disabled.
P11
1 = enabled.
2 = enabled with automatic cleaning
Enabling of automatic washing
P12
0 = disabled.
1 = enabled.
Enabling of initial washing
P13
0 = disabled.
1 = enabled.
Enabling of connection with the cash register
0 = No connection with the cash register.
P14
1 = First pay mode (CREDIT - DEBIT)
2 = First dispensing mode (CREDIT - DEBIT)
Enable continuous coffee dispensing
0 = Stop Start button disabled
P15
1 = Stop Start button enabled
2 = Start Stop button ON for 3 sec. (Purge)
Automatic daylight saving time management
0=Manual management
P16
1 = Daylight saving time according to European rules
2 = Daylight saving time according to USA rules
P17
User interface theme
Disable buzzer sound when pressing LCD keys
P18
0 = Buzzer operates normally
1 = Buzzer excluded
P19
Relevant time zone
P20
Minimum group temperature for group 1 dispensing
TECHNICIANS manual
Par.
P21
min
Def
MAX
Um
P22
°C
°C
°F
-
P23
0
0
2
P24
0
0
1
P25
1
3
4
-
P26
0
0
50
N/A
P27
0
1
1
P30
P31
0
1
1
N/A
P32
P33
P34
0
1
1
N/A
P35
P36
P37
0
1
1
N/A
P40
P41
0
0
1
N/A
P42
P43
P44
P45
0
0
1
N/A
P46
P47
0
0
1
N/A
P50
P51
P52
0
0
1
N/A
P53
P54
P55
0
0
2
N/A
P56
P57
P60
0
1
2
N/A
P61
P62
P63
P65
0
1
2
N/A
P66
P67
0
1
3
N/A
P68
0
0
1
N/A
P69
P70
0
2
37
N/A
P71
60
80
105
°C
Description
Minimum coffee boiler temperature for group 1
dispensing
Group 1 Temperature set
Group 1 coffee boiler Temperature set
Minimum Temperature set in group 1 standby
Minimum Temperature set in group 1 coffee boiler
standby
Temperature Delta set in group 1 standby
Minimum Temperature set in group 1 coffee boiler
standby
Minimum group temperature for group 2 dispensing
Minimum coffee boiler temperature for group 2
dispensing
Group 2 Temperature set
Group 2 coffee boiler Temperature set
Minimum Temperature set in group 2 standby
Minimum Temperature set in group 2 coffee boiler
standby
Temperature Delta set in group 2 standby
Minimum Temperature set in group 2 coffee boiler
standby
Minimum group temperature for group 3 dispensing
Minimum coffee boiler temperature for group 3
dispensing
Group 3 Temperature set
Group 3 coffee boiler Temperature set
Minimum Temperature set in group 3 standby
Minimum Temperature set in group 3 coffee boiler
standby
Temperature Delta set in group 3 standby
Minimum Temperature set in group 3 coffee boiler
standby
Minimum group temperature for group 4 dispensing
Minimum coffee boiler temperature for group 4
dispensing
Group 4 Temperature set
Group 4 coffee boiler Temperature set
Minimum Temperature set in group 4 standby
Minimum Temperature set in group 4 coffee boiler
standby
Temperature Delta set in group 4 standby
Minimum Temperature set in group 4 coffee boiler
standby
Coffee boiler minimum temperature.
Coffee boiler maximum temperature.
Group minimum temperature.
Group maximum temperature.
On time solenoid valve group during pre-infusion.
Off time solenoid valve group during pre-infusion.
Coffee boiler full recognition pressure (machines
with analog pressure transducer in coffee boilers).
Group SV opening time during the coffee boiler filling
phase for air evacuation.
Delay due to closure of all the group solenoid valves
in the initial loading stage.
Group heating timeout. (P-band input)
Coffee boiler heating timeout. (P-band input)
min
Def
MAX
Um
60
80
110
°C
P62
93
P63
°C
P60
93
P61
°C
0
60
75
°C
0
60
75
°C
0
0
50
°C
0
20
50
°C
60
80
105
°C
60
80
110
°C
P62
93
P63
°C
P60
93
P61
°C
0
60
75
°C
0
60
75
°C
0
0
50
°C
0
20
50
°C
60
80
105
°C
60
80
110
°C
P62
93
P63
°C
P60
93
P61
°C
0
60
75
°C
0
60
75
°C
0
0
50
°C
0
20
50
°C
60
80
105
°C
60
80
110
°C
P62
93
P63
°C
P60
93
P61
°C
0
60
75
°C
0
60
75
°C
0
0
50
°C
0
20
50
°C
0
60
P61
°C
P60
110
120
°C
0
60
P63
°C
P62
105
120
°C
0
0.5
10
S
0
1.5
10
S
0.1
2
6
bar
0
10
20
s
0
2
20
s
0
45
255
Min
0
45
255
Min
69
76
of

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Myconcept evdp 3grMyconcept evdp 4gr

Table of Contents