Safety Features; Compressor Overheating Discharge Protection; Abnormal Operation Protection Of The Relay; Abnormal Operation Protection Of Electronic Expansion Valve - A.O. Smith HPI-40C1.0AT User Manual

Heat pump water heater
Table of Contents

Advertisement

Safety Feature

Compressor overheating discharge protection

The system will promptly stop the operation of the compressor to ensure safety in case the compressor
overheats due to the fault of the water heater.

Abnormal operation protection of the relay

The system will shut down all loads to prevent overvoltage, fire and other incident in case the water
temperature continues rising after the stop of pump due to the fault of the relay.

Abnormal operation protection of electronic expansion valve

The system will stop the operation of the compressor to protect the pump due to the electronic expansion
valve not working or not working properly.

High and low voltage protection

The system will promptly shut down all loads to protect the component and prevent the electric appliances
accidents due to the high or low voltage beyond the safety level.

Refrigerant leakage protection

The system will promptly stop the operation of the compressor protect the pump in case the leakage of the
refrigerant.

High water temperature protection

The system will shut down all loads to ensure safety in case any of the multiple sensors inside the water
heater reaches
90°C.

High Temperature Limit Protection Switch

A high temperature limit protection thermal cutout is equipped on the
Relief valve
heat pump water heater. The switch cuts off the phase and neutral line
instantaneously and simultaneously to guarantee safety in case water
temperature reaches the high temp limited due to water heater fault. If
Drain valve
this happens, please contact local authorized dealer.

Temperature and pressure relief valve

The water heater has a temperature and pressure relief valve, model
number: NPT3/4 1.03(see Figure 1), Default setting by factory is at
2
Figure
Temperature and pressure relief
1.03MPa and not
adjustable.
The valve must be installed in the
position shown in Figure 1. The valve will release the pressure
automatically when the pressure in the water heater exceeds 1.03MPa or the temperature exceeds 99°C. .
This valve must install with a drain pipe at its outlet, and the pipe should be installed downward in a
frost-free environment, the diversion pipe overflow water should be discharged to floor drain.
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hpi-40c1.0aeHpi-50c1.0atHpi-50c1.0ae