Water Heater HSE-HNS 50, 60, 80 Litres HIG-VNS-006 THE SAFEST GAS WATER HEATER Dual Solenoid Three Burners Ignition Pin Valve Carbon Monoxide Corrosion Resistant Warranty* Detector (Oxygen free copper exchanger) (Optional) User Guide * Conditions Apply...
Page 2
Congratulations! And welcome to the A. O. Smith family. We would like to thank you for the trust you have shown in choosing an A. O. Smith water heater. You can be sure it will live up to your expectations. Thousands of delighted users all over the world trust A.
What's in the box? Box 1: Main Box User Guide Gas Water Heater Mounting Screws Swivel & Accessories connector Box 2: Accessory Box Outlet Vent Pipe Corrugated Tube Straight Pipe Elbow Vent Pipe Contents User instructions..................1 Safety information ..................2 Specifications....................4 Key features ....................6...
User Instructions Please read the instructions carefully before the installation or operation of the water heater. This user guide is meant for your future reference and is applicable for the instant gas water heater model HIG-VNS-006. • Only A. O. Smith recommended professional installers will install the A. O. Smith gas water heater.
Warning: • Close the gas supply valve. • Carefully plan where you install the heater. If the gas water heater is not • Do not try to light any appliance. installed properly, fatal accidents can result from lack of air, carbon monoxide poisoning or fire.
Page 6
Vapors from flammable liquids will explode and catch fire causing death or severe burns. Do not use or store flammable products such as petrol, diesel, kerosene, solvents or adhesives in the same room or area near the water heater. Keep flammable products: 1.
Specifications Model HIG-VNS-006 † Gas Type Piped Natural Gas Voltage/ Frequency (Wattage) (V/Hz[W]) 220~/50[45] Temperature Rise and Hot Water Output (ºC@L/min) 25 @ 6 Venting Type Power Vented Ignition System Automatic Electric Pulse Ignition Water Pressure (MPa) Min 0.02, Max 1.2 Rated Gas Pressure (millibars) Rated Heat Input [kW] Controlling Type...
Page 8
Dimensions Model HIG-VNS-006 A [mm] B [mm] C [mm] Part Descriptors 1. Water Inlet 2. Hot Water Outlet 3. Gas Inlet 4. Child Lock 5. Connector (CO Detector) 6. Gas-flow Control Knob 7. Winter/Summer Setting Knob 8. Straight Pipe 9. Elbow Vent Pipe 10.
This gas water heater has three burners which results in optimum combustion of gas. This gas water heater is amongst one of the lowest gas consumption models available in the industry and is the most economical to operate. It also largely reduces carbon monoxide emissions.
25 Minutes Timer (Child Lock) If this gas water heater is left unattended or used in ON condition for more than 25 minutes, then the timer cuts off the gas supply and the ignition to ensure safety & avoid wastage of natural gas.
• It is recommended to use CO detector. Only A. O. Smith recommended CO detector should be used for this gas water heater. • Should overheating occur or the gas supply fail to shut off, turn off the manual gas valve to the water heater.
Mounting Instructions Warning: Before starting installation: • Check that there are no loose parts inside the water heater. • Ensure that gas pipe, gas valve and burner has no damages and are properly fitted. Do’s • Ensure that the flue terminal is clear of any combustible material.
Venting Instructions Warning: • Improper venting of this appliance can result in excessive levels of carbon monoxide which can result in severe personal injury or loss of life. • Improper installation can cause nausea or asphyxiation, severe injury or death from carbon monoxide and flue gases poisoning.
Operating Instructions For safety read before operating the water heater Warning: • If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. • The water heater must be installed by a professional installers recommended by A.
Maintenance and Cleaning Repairs and maintenance should be performed by an A. O. Smith service technician. Verify proper operation after servicing. It is imperative that control compartments, burners and circulating air passage ways of the water heater be kept clean. 1.
Error Codes Fault Code Ignition failure Heating LED light flashes 1 time Flame failure Heating LED light flashes 2 times CO is out of limits* Heating LED light flashes 4 times Fan fault Heating LED light flashes 5 times Flame sensor fault Heating LED light flashes 8 times High temp.
Warranty Product warranty Your A. O. Smith water heater is warranted against defects arising from faulty design, workmanship and materials for a period of 24 months from the date of the invoice, subject to the following conditions: The customer will notify the Company promptly about defects noticed and give the Company or its authorised service provider adequate opportunity to inspect, test Extended...
General Terms of Warranty The “goods” shall mean the goods described in the purchase agreement. “The customer” shall mean the original purchaser under the purchase agreement. “The Company” shall mean A. O. Smith India Water Heating Pvt. Ltd. The “Purchase Agreement” shall mean the General Terms and Conditions of Sale agreed upon by the customer and the Company as printed on the Invoice.
Warranty Card Warranty Card (Customer Copy) (To be retained by the Customer) Unit Serial Number: Invoice Number: Dated: Customer's Name and Address: Model: Capacity: Dealer’s Stamp and Signature Warranty Card Warranty Card (Company Copy) (To be sent back to the Company) Unit Serial Number: Invoice Number: Dated:...
Service and Maintenance Toll Free Customer Care Centre Helpline at 1.800.103.2468 E-mail ID: aosmithcs@hotwater.com Registered Office A. O. Smith India Water Heating Private Limited Plot No. 300, Phase-2, KIADB Industrial Area, Harohalli, Kanakapura Taluk, Ramanagara District - 562 112, Karnataka, India. Toll Free No.: 1.800.103.2468 Website: www.aosmithindia.com Regional Office...
Page 24
Manufactured by A. O. Smith India Water Heating Private Limited Plot No. 300, Phase-2, KIADB Industrial Area, Harohalli, Kanakapura Taluk, Ramanagara District - 562 112, Karnataka, India. Toll Free: 1.800.103.2468 Website: www.aosmithindia.com...