Temperature and Humidity
Maintain the specified temperature and humidity even when the machine is not in use. If temperatures are
too high or too low, it may cause malfunction.
During operation: Temperature 20 to 32˚C (68 to 90˚F), relative humidity 35 to 80%
(no condensation)
During non-operation: Temperature 5 to 40˚C (41 to 104˚F), relative humidity 20 to
80% (no condensation)
Installation Space
The space shown in the figure is required in order to use this machine.
When using the main unit only
(rigid media tables are not used)
4300 mm (169.3 in.)
3300 mm (129.9 in.)
Unit Space
Work Space
Air Ventilation
This machine emits a small amount of volatile compounds during printing and for some time after printing,
which may cause irritation of your eyes, nose, and throat. To use this machine, make sure to install ventilating
equipment for adequate ventilation.
P. 58, "7. Installation of Ventilating Equipment"
1. Installation Environment
When using the rigid media table
4300 mm (169.3 in.)
3300 mm (129.9 in.)
Unit Space
Work Space
19