On-Board Outputs; Circuit Protection; Total Available Power - Bosch B6512 Installation Manual

Hide thumbs Also See for B6512:
Table of Contents

Advertisement

Control panels
5

On-board outputs

The control panel provides one configurable (power, common, dry) and two open collector on-
board outputs.
5.1

Circuit protection

The powered outputs come with circuit protection.
Three self-resetting circuit breakers protect the control panel from short circuits on the
continuous and programmable power outputs. Each breaker protects a separate terminal:
Notice!
UL requirement
Supervise devices powered from a power output.
5.2

Total available power

The control panel produces up to 800 mA of combined power at 12.0 VDC nominal to power
peripheral devices. The outputs listed below and OUTPUT A share the available power.
AUX terminal (auxiliary power)
AUX
Powers devices requiring continuous power (for example, motion detectors).
R/PWR terminal and power output of the interconnect connector (SDI2 power)
R
PWR
Power SDI2 devices such as keypads and octo-input modules.
Plug-in module connector
Connect plug-in modules such as the B444, B444-A, or B444-V.
OUTPUT A
NO
OUTPUT A
Configure Output A as a dry contact (contact rating is 3 Amps), switched common (sink
current), or a powered output. As a powered output, it can provide alarm power or switched
auxiliary power. The default configuration for Output A makes it a powered output providing
alarm power. Use OUTPUT PARAMETERS in RPS or in the Installer Services Portal
programming tool (available in Europe, Middle East, Africa, and China) to configure
programmable outputs.
Bosch Security Systems B.V.
AUX (auxiliary power) terminal.
C terminal of OUTPUT A.
PWR/R terminal (power) of the SDI2 terminal block.
C
NC
UL Installation manual
On-board outputs | en
19
2019-12 | 10 | F.01U.287.185