Description Of Terminals On Main Circuit - Delta VFD-VJ Series User Manual

Air cooled hybrid servo drive
Hide thumbs Also See for VFD-VJ Series:
Table of Contents

Advertisement

VFD-VJ Air Cooled | 2. Wiring

2-2 Description of Terminals on Main Circuit

Power Supply
EMI Filter
R/L1
S/L2
U/T1
V/T2
Motor
Power supply
Fuse/NFB
Fuse /
(Optional)
No-Fuse
Breaker
Magnetic
contactor
Magnetic
contactor
(Optional)
Input AC
Line Reactor
Input AC Line
Reactor
(Optional)
Zero-phase
Reactor
Zero-phase
Reactor
(Ferrite Core
Common
T/L3
Choke)
(Optional)
B1
B2
EMI filter
(Optional)
W/T3
Brake Resistor
(Optional)
Zero-phase
Reactor
Output AC Line
Reactor
Output AC
Line Reactor
(Optional)
Items
Please follow the specific power supply
requirements shown in Chapter 01.
There may be an inrush current during
power up. Please check the chart of
Appendix A-2 and select the correct
fuse with rated current. Use of an NFB
is optional.
Please do not use a Magnetic
contactor as the I/O switch of the AC
motor drive, as it will reduce the
operating life cycle of the AC drive.
Used to improve the input power factor,
to reduce harmonics and provide
protection from AC line disturbances.
(surges, switching spikes, short
interruptions, etc.). AC line reactor
should be installed when the power
supply capacity is 500kVA or more and
exceeds 6 times the inverter capacity,
or the mains wiring distance
Zero phase reactors are used to
reduce radio noise especially when
audio equipment is installed near the
inverter. Effective for noise reduction
on both the input and output sides.
Attenuation quality is good for a wide
range from AM band to 10MHz.
Appendix A specifies the zero phase
reactor. (RF220X00A)
To reduce electromagnetic
interference, please refer to Appendix
A for more details.
Used to reduce the deceleration time of
the motor. Please refer to the chart in
Appendix A for specific Brake
Resistors.
Motor surge voltage amplitude
depends on motor cable length. For
applications with long motor cable
(>20m), it is necessary to install a
reactor at the inverter output side.
2-8
Explanations
10m.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents