CAUTION: The cross-sectional area of the conductors in the Power Supply Cord shall not be less
than 4 mm
2
Required tools
•
Flat torque screw driver 4 mm
•
Adjustable wrench
Required parts
•
(for 3W+N+PE, 230/400V) Certified power cable, minimum 4 mm² or AWG 10, 500V rated, cable diameter
between 11 mm and 21 mm or
•
(for 3W+PE, 208V) Certified power cable, minimum 4 mm² or AWG 10, 300V rated, cable diameter
between 11 mm and 21 mm
•
Circuit breaker maximum 40A
How to connect
1.
Remove the back cover.
2.
Remove the power input cover.
3.
Loosen the cable gland fixation ring (1).
Note: The cable gland (1) is specified for cables with a diameter between 11mm and 21mm.
Image 3-12: Power cable connection
4.
Push the stripped power supply cable through the cable gland. When using a flexible power cord, make sure
that each conductor end is provided with an end sleeve.
Fix the cable in the cable gland by securing ring 1 with an adjustable wrench.
5.
Connect the power cord with the terminal barrier strip. Use a flat torque screw driver set to 1.4 Nm.
Always connect the ground wire (PE) with the connector indicated with PE on the terminal barrier strip.
If a neutral conductor is available, connect always to the connector indicated with N on the terminal barrier
strip
or AWG 10.
1
Physical installation
R5905754 /13
DPxK-32B
31