MASTER PROGRAMMING MODE

When.the.Master.Programming.Mode.is.entered,.all.available.
option.setting.displays.may.be.viewed.and.set.as.needed..
Depending.on.current.option.settings,.some.parameters.cannot.
be.viewed.or.set.
Setting the Time of Day
1.. Press.and.hold.either.the.Up.or.Down.buttons.until.the.
programming.icon.replaces.the.service.icon.and.the.
parameter.display.reads.TD.
2.. Adjust.the.displayed.time.with.the.Up.and.Down.buttons.
3.. When.the.desired.time.is.set,.press.the.Extra.Cycle.button.to.
resume.normal.operation..The.unit.will.also.return.to.normal.
operation.after.5.seconds.if.no.buttons.are.pressed.
Entering Master Programming Mode
Set.the.Time.Of.Day.display.to.12:01.P.M..Press.the.Extra.Cycle.
button.(to.exit.Setting.Time.of.Day.mode)..Then.press.and.hold.
the.Up.and.Down.buttons.together.until.the.programming.icon.
replaces.the.service.icon.and.the.Display.Format.screen.appears..
Exiting Master Programming Mode
Press.the.Extra.Cycle.button.to.accept.the.displayed.settings.
and.cycle.to.the.next.parameter..Press.the.Extra.Cycle.button.
at.the.last.parameter.to.save.all.settings.and.return.to.normal.
operation..The.control.will.automatically.disregard.any.
programming.changes.and.return.to.normal.operation.if.it.is.
left.in.Master.Programming.mode.for.five.minutes.without.any.
keypad.input.
Resets
Soft Reset:.Press.and.hold.the.Extra.Cycle.and.Down.buttons.
for.25.seconds.while.in.normal.Service.mode...This.resets.all.
parameters.to.the.system.default.values,.except.the.volume.
remaining.in.meter.immediate.or.meter.delayed.systems.and.
days.since.regeneration.in.the.time.clock.system.
Master Reset: Hold.the.Extra.Cycle.button.while.powering.up.
the.unit..This.resets.all.of.the.parameters.in.the.unit..Check.and.
verify.the.choices.selected.in.Master.Programming.Mode.
1. Display Format (Display Code DF)
This.is.the.first.screen.that.appears.when.entering.Master.
Programming.Mode..The.Display.Format.setting.specifies.the.
unit.of.measure.that.will.be.used.for.volume.and.how.the.control.
will.display.the.Time.of.Day..This.option.setting.is.identified.by.
"DF".in.the.upper.left.hand.corner.of.the.screen..There.are.three.
possible.settings:
Display Format Setting
GAL
Ltr
12 • Pentair.5600SXT.Softener.System
Unit of Volume
Time Display
U.S..Gallons
12-Hour.AM/PM
Liters
24-Hour
2. Valve Type (Display Code VT)
Press.the.Extra.Cycle.button..Use.this.display.to.set.the.Valve.
Type..The.Valve.Type.setting.specifies.the.type.of.cycle.that.the.
valve.follows.during.regeneration..Note.that.some.valve.types.
require.that.the.valve.be.built.with.specific.subcomponents..
Ensure.the.valve.is.configured.properly.before.changing.the.Valve.
Type.setting..This.option.setting.is.identified.by."VT".in.the.upper.
left.hand.corner.of.the.screen..There.are.
6.possible.settings:
Abbreviation
dF1b
Standard.Downflow/Upflow,.Single.Backwash
dF2b
Standard.Downflow/Upflow,.Double.Backwash
Fltr
UFbd
UFtr
Othr
3. Control Type (Display Code CT)
Press.the.Extra.Cycle.button..Use.this.display.to.set.the.Control.
Type..This.specifies.how.the.control.determines.when.to.trigger.
a.regeneration..For.details.on.how.the.various.options.function,.
refer.to.the."Timer.Operation".section.of.this.service.manual..This.
option.setting.is.identified.by."CT".in.the.upper.left.hand.corner.of.
the.screen..There.are.four.possible.settings:
Meter.Delayed:.
Fd
Meter.Immediate:.
FI
Time.Clock:.
tc
Day.of.Week:.
dAY
4. Number of Tanks (Display Code NT)
Press.the.Extra.Cycle.button..Use.this.display.to.set.the.Number.
of.Tanks.in.your.system..This.option.setting.is.identified.by."NT".in.
the.upper.left.hand.corner.of.the.screen..There.are.two.possible.
settings:
Single.Tank.System:. 1
Two-Tank.System:.
2
Parameter
Filter
Upflow.Brine.First
Upflow.Filter
Other