Slp297Uhnv Gas Furnace; Shipping And Packing List; Safety - Lennox DAVE SIGNATURE SL297UHNV Installation Instructions Manual

Gas furnace upflow/horizontal air discharge
Table of Contents

Advertisement

SL297UHNV Gas Furnace
The SL297UHNV Category IV gas furnace is shipped
ready for installation in the upflow or horizontal position.
The furnace is shipped with the bottom panel in place. The
bottom panel must be removed if the unit is to be installed
in horizontal or upflow applications with bottom return air.
The SL297UHNV is to be installed as Direct Vent gas
central furnace only. The furnace is equipped for in-
stallation in natural gas applications only.
NOTE - In Direct Vent installations, combustion air is tak-
en from outdoors and flue gases are discharged outdoors.
DIRECT VENT INSTALLATION
COMBUSTION
AIR INTAKE
OUTSIDE OF
HOUSE
FIGURE 2

Shipping and Packing List

Package 1 of 1 contains
1 - Assembled SL297UHNV unit
1 - Bag assembly containing the following:
1 - Snap bushing
1 - Snap plug
1 - Wire tie
1 - Condensate trap
1 - Condensate trap cap
1 - Condensate trap clamp
1 - 2" diameter debris screen
1 - 3/4" Threaded street elbow
Check equipment for shipping damage. If you find any
damage, immediately contact the last carrier. The follow-
ing items may also be ordered separately:
1 - Thermostat
1 - Return air base kit
1 - Horizontal suspension kit
Safety Information
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves and
protective clothing.
EXHAUST OUTLET
Danger of explosion.
There are circumstances in which odorant used with LP/
propane gas can lose its scent. In case of a leak, LP/
propane gas will settle close to the floor and may be
difficult to smell. An LP/propane leak detector should be
installed in all LP applications.
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional HVAC installer (or
equivalent), service agency or the gas supplier.
Use only the type of gas approved for use with this fur-
nace. Refer to unit nameplate.
SL297UHNV units are CSA International certified to ANSI
Z21.47 and CSA 2.3 standards.
Building Codes
In the USA, installation of gas furnaces must conform with
local building codes. In the absence of local codes, units
must be installed according to the current National Fuel
Gas Code (ANSI-Z223.1/NFPA 54). The National Fuel
Gas Code is available from the following address:
American National Standards Institute, Inc.
11 West 42nd Street
New York, NY 10036
In Canada, installation must conform with current National
Standard of Canada CSA-B149 Natural Gas and Propane
Installation Codes, local plumbing or waste water codes
and other applicable local codes.
Installation Locations
This furnace is CSA International certified for installation
clearances to combustible material as listed on the unit
nameplate and in the table in figure 6. Accessibility and
service clearances must take precedence over fire protec-
tion clearances.
NOTE - For installation on combustible floors, the furnace
shall not be installed directly on carpeting, tile, or other
combustible material other than wood flooring.
For installation in a residential garage, the furnace must
be installed so that the burner(s) and the ignition source
are located no less than 18 inches (457 mm) above the
floor. The furnace must be located or protected to avoid
physical damage by vehicles. When a furnace is installed
in a public garage, hangar, or other building that has a
hazardous atmosphere, the furnace must be installed ac-
cording to recommended good practice requirements and
current National Fuel Gas Code or CSA B149 standards.
NOTE - Furnace must be adjusted to obtain a temperature
rise within the range specified on the unit nameplate. Fail-
ure to do so may cause erratic limit operation and prema-
ture heat exchanger failure.
This SL297UHNV furnace must be installed so that its
electrical components are protected from water.
Page 4
DANGER
WARNING

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents