Testing and Simulation with COM 265
Specify actual values via function keys (<F2> "Value")
You can assign new actual values for retentive language elements and non-binary input parameters
in the control system flowchart. You need not exit the Simulator level to do so.
The following manipulations are possible:
New actual values for timers and counters
New values for word input parameters for timers, counters and comparators
Changing the status of an RS flipflop
All manipulations are displayed on the monitor screen.
Example: Changing the actual value of timer 1 from 50 ms to 100 ms
Set the cursor to the timer.
Select "Value" in the menu line by pressing function key <F2>.
The control system flowchart is faded out and replaced by the input field "New actual value".
Enter "10" for 100 ms.
Confirm your entry with <1> or <INSERT> .
Initial situation
1
1 - - -
I 0.0
>
S
KT 5.0
TV
I 0.1
R
5
The timer is set to "10" (100 ms) on the next IP 265 clock pulse.
Note
When manipulating timers, it is possible to change only the time (0 to 999). At the
simulator level, it is not possible to change the time base.
Remedy:
10-10
Q 0.0
Q
Quick change to the Editor with <CORR>.
Result
1
1 - - -
I 0.0
>
S
KT 5.0
TV
I 0.1
R
Q
10
EWA 4NEB 812 6130-02a
IP 265
Q 0.0