Apply this label to drive bays 12–15 if an AnyBay 8-bay backplane is installed to drive bays 8–15.
• 0-15 (NVMe)
Apply this label to drive bays 0–15 if two NVMe 8-bay backplanes are installed to drive bays 0–
15.
• 16-19 (NVMe)
Apply this label to drive bays 16–19 if a NVMe 8-bay backplane is installed to drive bays 16–19.
• 16-23 (NVMe)
Apply this label to drive bays 16–23 if a NVMe 8-bay backplane is installed to drive bays 16–23.
The following illustration shows the location for applying the drive bay labels to the server models
with AnyBay 8-bay backplanes installed. The location is the same for applying the drive bay labels
to server models with SATA/SAS 8-bay backplanes installed. Ensure that the drive bay labels are
stuck in the correct location. The labels help you to locate the correct drive during problem
determination.
Figure 83. Drive bay labels for server models with AnyBay 8-bay backplanes installed
After installing the 2.5-inch-drive backplane, connect the cables to the system board. For information about
the cable routing, see "Internal cable routing" on page 35.

Install the 3.5-inch-drive backplane

Use this information to install the 3.5-inch-drive backplane. This topic applies only to server models that
support 3.5-inch-drive backplanes.
"Read the
installation
Guidelines" on
page 126
Note: The procedure is based on the scenario that you want to install the backplane for up to twelve 3.5-
inch drives. The procedure is similar for the backplane for up to eight 3.5-inch drives.
Before installing the 3.5-inch-drive backplane, touch the static-protective package that contains the new
backplane to any unpainted surface on the outside of the server. Then, take the new backplane out of the
package and place it on a static-protective surface.
To install the 3.5-inch-drive backplane, complete the following steps:
Watch the procedure. A video of the installation process is available:
• Youtube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-A25P7vBoGa_wn7D7XTgDS_
• Youku:
http://list.youku.com/albumlist/show/id_50483444
156
ThinkSystem SR650 Setup Guide
"Power off
the server for
this task" on
page 194
"ATTENTION:
Static Sensitive Device
Ground package before opening"
on page 127

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinksystem sr650 7x05Thinksystem sr650 7x06

Table of Contents