12.13. Removal of R3-P.C.Board
(1)
Loosen the 1 screw until it idles and open the lamp unit cover.
(2)
Unscrew the 2 screws and remove the R3-P.C.Board.
12.14. Removal of S-P.C.Board
(1)
Remove the upper case according to the section 12.2. "Removal
of Upper Case".
(2)
Unscrew the 2 screws and remove the blindfold board.
(3)
Unscrew the 6 screws and remove the connection terminals
panel.
35
PT-D10000U / PT-D10000E / PT-DW10000U / PT-DW10000E