Self-Diagnosis Display - Panasonic PT-D10000U Service Manual

Hide thumbs Also See for PT-D10000U:
Table of Contents

Advertisement

PT-D10000U / PT-D10000E / PT-DW10000U / PT-DW10000E
· COLOR FILTER
NONE: Default setting
INSTALLED: When installing the color filter that expands the color region
· UNIFORMITY
Sets the value of color unevenness correction.
· FRONT LAMP LED
ON: Default setting
OFF: Prohibits a green lighting.
· LAMP CHANGE MUTE
ON: Turns off the projection temporarily when switching the lighting lamp.
OFF: Does not turn off the projection when switching the lighting lamp. However, a video noise might appear momentarily in the
projection.
· LENS SHIFT CALIBRATION
Calibrates the limit and the home position of the lens shift.
Execute LENS SHIFT CALIBRATION according to the procedure of the next paragraph when replacing the lens mount, LH-
Module or LV-Module.
4.3.4.
Execution of LENS SHIFT CALIBRATION
1. Enter the serviceman mode according to the section 4.1. "Setting to Serviceman Mode".
2. Select LENS SHIFT CALIBRATION in EXTRA OPTION.
3. Press the ENTER button. When you execute LENS SHIFT CALIBRATION, press the ENTER button again when displayed
"SURE?".
4. The lens moves up/down/right/left, and the limit and the home position values of the shift are set again automatically.
5. When the lens stops, re-setting is finished.

5 Self-diagnosis Display

There is a self-diagnosis display located at the side of the projector which automatically displays error details when an error occurs.
If an error-code is displayed in the self-diagnosis display, check the part of the cause according to the content of the error-code
table below.
5.1.
Error-code Table
Error-code
U11
Temperature warning (IN)
U12
Temperature warning (OPT)
U13
Temperature warning (OUT)
U14
Low temperature warning (OPT)
U21
Temperature error (IN)
U22
Temperature error (OPT)
U23
Temperature error (OUT)
U24
Low temperature error (OPT)
U41
Lamp 1 operating time warning
U42
Lamp 2 operating time warning
U43
Lamp 3 operating time warning
U44
Lamp 4 operating time warning
U61
Lamp 1: 2 000 hour operating time
exceeded
U62
Lamp 2: 2 000 hour operating time
exceeded
U63
Lamp 3: 2 000 hour operating time
exceeded
U64
Lamp 4: 2 000 hour operating time
exceeded
Contents
Shutdown
*1
*2
*2
*2
*2
Error display condition
Intake air temperature is the specific value or
higher.
Optical module temperature is the specific
value or higher.
Lamp surroundings temperature is the specific
value or higher.
Optical module temperature is less than the
specific value.
Intake air temperature is the specific value or
higher.
Optical module temperature is the specific
value or higher.
Lamp surroundings temperature is the specific
value or higher.
Optical module temperature is less than 5°C.
Lamp cumulative usage time is 1 800 hour or
longer.
Lamp cumulative usage time is 2 000 hour or
longer.
14
Remarks
After turning on the power, the
shutdown processing is not
done for 2.5 minutes.
LAMP monitor lights in red.
After turning on the lamp, it will
turn off in 10 minutes. LAMP
monitor lights in red.