Panasonic PT-D10000U Service Manual page 15

Hide thumbs Also See for PT-D10000U:
Table of Contents

Advertisement

Error-code
Contents
U51
Lamp 1 going out
U52
Lamp 2 going out
U53
Lamp 3 going out
U54
Lamp 4 going out
U51
Lamp 1 lighting failure
U52
Lamp 2 lighting failure
U53
Lamp 3 lighting failure
U54
Lamp 4 lighting failure
U70
Air filter unit not installed
U71
Lamp 1 not installed
U72
Lamp 2 not installed
U73
Lamp 3 not installed
U74
Lamp 4 not installed
U81
AC power supply voltage drop
warning (less than 90 V)
U91
Lamp unit cover is not closed
H11
Thermosensor disconnected (IN)
H12
Thermosensor disconnected (OPT)
H13
Thermosensor
(OUT)
H18
Airflow sensor disconnected
U04
Air filter is blocked
H01
Internal clock battery replacement
FE1
Fan error 1: P-UNIT FAN
FE2
Fan error 2: LAMP1 FAN
FE3
Fan error 3: LAMP2 FAN
FE4
Fan error 4: LAMP3 FAN
FE5
Fan error 5: LAMP4 FAN
FE6
Fan error 6: BALLAST1 FAN
FE7
Fan error 7: BALLAST3 FAN
FE8
Fan error 8: RADIATOR FAN
FE9
Fan error 9: EXAUST FAN C
FF0
Fan error 10: EXAUST FAN L
FF1
Fan error 11: EXAUST FAN R
FF2
Fan error 12: R-DMD FAN
FF3
Fan (Module) error 13: G-LIQUID
COOLING
FF4
Fan (Module) error 14: B-LIQUID
COOLING
FF5
Fan error 15: C-PRISM FAN
FF6
Fan error 16: L-PRISM FAN
FF7
Fan error 17: BALLAST2 FAN
FF8
Fan error 18: BALLAST4 FAN
F11
Shutter error
F12
Dynamic iris error
F13
Air filter unit error
F21
2.5 V DC error
F22
3.3 V DC error
F23
5.0 V DC error
F41
Lamp 1 memory error
F42
Lamp 2 memory error
F43
Lamp 3 memory error
F44
Lamp 4 memory error
FP1
Lamp 1 PFC error
FP2
Lamp 2 PFC error
FP3
Lamp 3 PFC error
FP4
Lamp 4 PFC error
F91
FPGA1 configuration error
F92
FPGA2
(SXGA+)
error
F92
FPGA2 (FULL-HD) configuration
error
Shutdown
*2
Lamp goes out after turning on.
*2
*2
*2
*2
Lamp ignition failure
*2
*2
*2
Air filter unit is not installed.
Lamp is not installed (The lamp memory cannot
be read.)
AC power supply voltage drops.
Lamp unit cover is not closed for 1 second or
longer.
Intake air thermosensor is disconnected.
Optical module thermosensor is disconnected.
disconnected
Lamp
disconnected.
Airflow sensor is disconnected.
The air filter accumulates dust.
The date is before December 31, 2005 or after
January 1, 2036.
The fan stops for 5 seconds or longer.
Shutter error
Dynamic iris error
Air filter cleaning processing time-out
2.5 V DC error
3.3 V DC error
5.0 V DC error
*2
Lamp EEPROM is abnormal.
*2
*2
*2
*2
Lamp 1 PFC error
*2
Lamp 2 PFC error
*2
Lamp 3 PFC error
*2
Lamp 4 PFC error
A-P.C.Board is abnormal.
configuration
FH-Module is abnormal.
Error display condition
surroundings
thermosensor
15
PT-D10000U / PT-D10000E / PT-DW10000U / PT-DW10000E
Remarks
LAMP monitor blinks 3 times in
red.
LAMP monitor blinks 3 times in
red.
Confirms the installation when
turning on the power.
LAMP monitor blinks 3 times in
red.
If the cover is not closed when
turning on the power, it does
not turn on.
is
If this error occurs, the date is
reset on 00:00:00, January 1,
2006.
Power unit fan
Lamp fan 1
Lamp fan 2
Lamp fan 3
Lamp fan 4
Ballast fan 1
Ballast fan 3
Radiator fan
Exhaust fan (C)
Exhaust fan (L)
Exhaust fan (R)
R-DMD fan
Liquid cooling pump (G)
Liquid cooling pump (B)
Color prism fan
Lamp prism fan
Ballast fan 2
Ballast fan 4
LAMP monitor blinks 3 times in
red.
LAMP monitor blinks 3 times in
red.
for PT-D10000*
for PT-DW10000*

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt-d10000ePt-dw10000uPt-dw10000e

Table of Contents