STICK SETTING [System Menu]
This function sets the servo response speed (response) and dead
band width (hysteresis) relative to stick operation for each
condition. The operation feel of the stick can be adjusted to
match the in-flight aerobatics.
Call the setting screen shown below by selecting [STICK
SETTING] from the System Menu.
Response
setting
Response adjustment
1. Use the cursor lever to move the cursor to the set value
display of the stick whose response you want to adjust.
2. Use the dial to set the response.
Initial value : 4
Adjustment range : 1~16 (The larger the adjustment
value, the slower the response.)
Hysteresis adjustment
1. Use the cursor lever to move the cursor to the set value
display of the stick whose hysteresis you want to adjust.
2. Use the dial to adjust the response.
Initial value : 1
Adjustment range : 0~32 (The larger the adjustment
value, the larger the hysteresis.)
MULTIPROP CHANNEL
[Linkage Menu]
One channel can be expanded to 8 channels by using an
MPDX-1 (Multiprop Decoder). Up to two MPDX-1 can be used
with the 12Z system.
Multiprop function assignment
1. Open the function setting screen of the Linkage Menu,
and set the function of the channel to which you want to
connect the MPDX-1 to MULTIPROP1 or MULTIPROP2.
Screen with MULTIPROP1 and MULTIPROP2 set
Operation control setting method
1. After assigning the function as described above, use the
cursor lever to move the cursor to MP CH of the channel
( Update Modification Contents in the past )
Condition
group/single
switching
Hysteresis setting
you want to set to multiprop. Push the DATA button to
display the setting screen shown below.
2. Use the cursor lever to move the cursor to CH
CONTROL of the multiprop channel you want to set.
Push the DATA button to display the control selection
screen. Select control.
Reverse setting
*Use this function when you want to reverse the direction of servo
operation.
1. Open the servo reverse setting screen of the Linkage
Menu. Use the cursor lever to select MP CH of the
channel you want to set to multiprop. Push the DATA
button.
2. The multiprop channel reverse setting screen is
displayed. Use the cursor lever to move the cursor to the
channel whose direction of operation you want to reverse.
Use the dial to switch between NORM (normal) and REV
(reverse), and push the DATA button.
End point adjustment
1. Open the end point (ATV) setting screen of the Linkage
Menu. Use the cursor lever to select MP CH of the
channel you want to set to multiprop. Push the DATA
button.
2. The multiprop channel end point (ATV) setting screen is
displayed. Use the cursor lever to move the cursor to the
channel whose end point you want to adjust. Use the dial
to change the rate. (Left and right, up and down can be
adjusted individually.)
*When both MULTIPROP1 and MULTIPROP2 are set, pushing the
cursor lever switches the MULTIPROP1 and MULTIPROP2 displays.
- 11 -