Replacement Procedures For Redundant Systems (Options 61C, 81, 81C) - Nortel Meridian 1 Replacement Manual

Hardware replacement
Table of Contents

Advertisement

Replacement procedures for redundant systems
(Options 61C, 81, 81C)
To perform this procedure the following is required:
an Install Program diskette specific to your CP type
a CD-ROM containing generic system software
one Keycode diskette
Database diskette(s)
two NT5D61 IODU/C cards
two IODU/C Security Devices
a Database Transfer Utility diskette to archive the IOP/CMDU database
on 2MB floppy diskettes.
Note: The diskettes in the Software Install Kit are write protected.
Ensure that you unprotect the disks before installation.
Performing a data dump
Before starting this procedure, make a backup copy of the customer database
on a 4MB diskette using the data dump routine:
1
Log into the system
2
Load the Equipment Data Dump Program (LD 43). At the prompt, enter
LD 43
3
When "EDD000" appears on the terminal, enter
EDD
4
When "DATADUMP COMPLETE" and "DATABASE BACKUP
COMPLETE" appear on the terminal, enter
****
Replacing equipment
to load the program
to begin the data dump
to exit the program