8.7 Inner chute ASSY

(1) Pull down the Green envelope levers on both sides of the Fuser unit.
(2) Remove the two Taptite bind B M4x12 screws, and remove the Inner chute ASSY.
Positioning holes
Assembling Note:
• When attaching the Inner chute ASSY, engage the Hooks on the Inner chute ASSY
with the Positioning holes on the Top cover ASSY.
• After assembling the Inner chute ASSY, pull up the Green envelope levers on both
sides of the Fuser unit.
Top cover ASSY
Hooks
Fuser unit
Inner chute ASSY
Green envelope lever
Fig. 3-13
3-20
Fuser unit
Green
envelope lever
Taptite bind B
M4x12