SiE39-404
Outdoor Air Processing Unit
Model
H1 Cooling Capacity
H1 Heating Capacity
Casing
Dimensions: (H×W×D)
Rows×Stages×Fin
Coil (Cross
Pitch
Fin Coil)
Face Area
Model
Type
Motor Output ×
Number of Units
Fan
Air Flow Rate (H/L)
External Static
Pressure H4
Drive
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Liquid Pipes
Piping
Connections
Gas Pipes
Drain Pipe
Machine Weight (Mass)
Sound Level (220V) H3,H4
Safety Devices
Refrigerant Control
Standard Accessories
Connectable Outdoor Units H5,H6
Drawing No.
Notes:
H1. Specifications are based on the following conditions:
H2. Air intake filter is not supplied, so be sure to install the optional long-life filter or high-efficiency filter.
H3. Anechoic chamber conversion value, measured at a point 1.5m downward from the unit center.
H4. Valves measured at 220 V.
H5. Within the range that the total capacity of indoor units is 50 to 100%, it is possible to connect to the
H6. It is not possible to connect to the 5 HP outdoor unit. Not available for Heat Recovery type and VRV II-S
· This equipment cannot be incorporated into the refrigerant piping system or remote group control of the
Specifications
FXMQ125MFV1
kcal/h
12,000
Btu/h
47,800
kW
14.0
kcal/h
7,700
Btu/h
30,000
kW
8.9
Galvanized Steel Plate
mm
470×744×1,100
mm
3×26×2.0
0.28
D13/4G2DA1
Sirocco Fan
W
380×1
m³/min
18
cfm
635
Pa
185
Direct Drive
Microprocessor Thermostat for
Cooling and Heating
Glass Fiber
H2
9.5mm
(Flare Connection)
15.9mm
(Flare Connection)
(mm)
PS1B (female thread)
kg
86
dBA
42
Fuse
Thermal Protector
for Fan Motor
Electronic Expansion Valve
Operation Manual, Installation Manual,
Sealing Pads, Screws, Clamps.
RXYQ8~48MY1B
3D046147A
· Cooling: Outdoor temp. of 33°CDB, 28°CWB (68% RH). and discharge temp. of 18°CDB
· Heating: Outdoor temp. of 0°CDB, -2.9°CWB (50% RH). and discharge temp. of 25°CDB
· Equivalent reference piping length: 7.5m (0m Horizontal)
· At 220V
Prease mount it in the duct system of the suction side. Select its colorimetric method (gravity method)
50% or more.
These values (measured at 220V) are normally somewhat higher during actual operation as a result of
ambient conditions.
outdoor unit.
series.
VRV II system.
FXMQ200MFV1
19,300
76,500
22.4
12,000
47,500
13.9
Galvanized Steel Plate
470×1,380×1,100
3×26×2.0
0.65
D13/4G2DA1
Sirocco Fan
380×1
28
988
225
Direct Drive
Microprocessor Thermostat for
Cooling and Heating
Glass Fiber
H2
9.5mm
(Flare Connection)
19.1mm
(Brazing Connection)
PS1B (female thread)
123
47
Fuse
Thermal Protector
for Fan Motor
Electronic Expansion Valve
Operation Manual, Installation Manual,
Sealing Pads, Connection Pipes,
Screws, Clamps.
RXYQ8~48MY1B
3D046147A
Specifications
FXMQ250MFV1
24,100
95,600
28.0
15,000
59,400
17.4
Galvanized Steel Plate
470×1,380×1,100
3×26×2.0
0.65
D13/4G2DA1
Sirocco Fan
380×1
35
1,236
205
Direct Drive
Microprocessor Thermostat for
Cooling and Heating
Glass Fiber
H2
9.5mm
(Flare Connection)
22.2mm
(Brazing Connection)
PS1B (female thread)
123
47
Fuse
Thermal Protector
for Fan Motor
Electronic Expansion Valve
Operation Manual, Installation Manual,
Sealing Pads, Connection Pipes,
Screws, Clamps.
RXYQ10~48MY1B
3D046147A
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
47