SiE39-404

8. Pressure Sensor

Detected Pressure
P
P
H
L
(kg/cm²)
MPa
51.0 5.0
45.9 4.5
40.8 4.0
35.7 3.5
30.6 3.0
25.5 2.5
20.4 2.0
15.3 1.5
10.2 1.0
5.1
0.5
0
-5.1 -0.5
-0.5
Appendix
P
= 1.38V-0.69
H
P
= 0.57V-0.28
L
P
: High pressure (MPa)
H
V
: Low pressure (MPa)
L
V : Voltage (V)
0
0.5
1
Output Voltage (V
P
: Detected Pressure [High Side] MPa
H
P
: Detected Pressure [Low Side] MPa
L
V
: Output Voltage [High Side] V
H
V
: Output Voltage [Low Side] V