Specifications
1.1.2 60Hz
Model Name
1 / 2 Cooling Capacity
3 / 4 Cooling Capacity
5 Heating Capacity
Casing Color
Dimensions: (H×W×D)
Heat Exchanger
Type
Piston Displacement
Number of Revolutions
Comp.
Motor Output×Number
of Units
Starting Method
Type
Motor Output
Fan
Air Flow Rate
Drive
Liquid Pipe
Connecting
Pipes
Gas Pipe
Product Mass (Machine Weight)
6 Sound Level
Safety Devices
Defrost Method
Capacity Control
Refrigerant Name
Refrigerant
Charge
Control
Refrigerator Oil
Standard Accessories
Drawing No.
Notes:
1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp. : 35°CDB.
2 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp. : 46°CDB.
3 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 35°CDB.
4 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 46°CDB.
5 Indoor temp. : 20°CDB / outdoor temp. : 7°CDB, 6°CWB.
6 Sound level : Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height
7 The units with anti-corrosion treatment will be available as standard. Please specify the suffix "E" as
12
RXYQ8MYLK(E)
RT
Btu / h
78,800 / 77,800
kcal / h
19,900 / 19,600
kW
RT
Btu / h
76,400 / 76,400
kcal / h
19,300 / 19,300
kW
RT
Btu / h
kcal / h
kW
Without (E): Ivory White (5Y7.5 / 1)
With (E): Light Camel (2.5Y6.5 / 1.5)
mm
1600×1240×765
Hermetically Sealed Scroll Type
m³/h
r.p.m
kW
Direct on line (inverter drive)
kW
m³/min
φ9.5 (Flare Connection)
mm
φ19.1 (Flare Connection)
mm
kg
dBA
High Pressure Switch, Fan Driver Overload Protector,
Over Current Relay, Inverter Overload Protector,
Fusible Plugs
%
kg
Electronic Expansion Valve
Refer to the nameplate of compressor
Installation Manual, Operation Manual, Connection Pipes,
Clamps
of 1.5m. The Sound level of "Combination Unit" is a supposed value. During actual operation, these
values are normally somewhat higher as a result of ambient conditions.
RXYQ8MYLKE.
The Reference Number
C~: Partly corrected drawings.
J~: Original drawing is Japanese
V~: Printing Convenience
6.6 / 6.5
23.1 / 22.8
6.4 / 6.4
22.4 / 22.4
7.1
85,300
21,500
25.0
Cross Fin Coil
13.72+10.53
6480, 2900
(0.7+4.5)×1
Propeller Fan
0.75×1
210
Direct Drive
268
60
Deicer
14~100
R-410A
9.4
C: 4D050535
RXYQ10MYLK(E)
8.0 / 6.8
96,200 / 82,200
24,300 / 20,700
28.2 / 24.1
8.0 / 6.8
95,500 / 82,200
24,100 / 20,700
28.0 / 24.1
8.9
107,000
27,100
31.5
Without (E): Ivory White (5Y7.5 / 1)
With (E): Light Camel (2.5Y6.5 / 1.5)
1600×1240×765
Cross Fin Coil
Hermetically Sealed Scroll Type
13.72+10.53
6480, 2900
(1.6+4.5)×1
Direct on line (inverter drive)
Propeller Fan
0.75×1
210
Direct Drive
φ9.5 (Flare Connection)
φ22.2 (Brazing Connection)
268
60
High Pressure Switch, Fan Driver Overload Protector,
Over Current Relay, Inverter Overload Protector,
Fusible Plugs
Deicer
14~100
R-410A
9.6
Electronic Expansion Valve
Refer to the nameplate of compressor
Installation Manual, Operation Manual, Connection Pipes,
Clamps
C: 4D050536
Conversion Formulae
cfm=m³/min×35.3
Si39-502A
RT=kW×0.284
Btu/h=kW×3412
kcal/h=kW×860
Specifications