864 - Details; 864 - Installation Overview - FireplaceXtrordinair CoolSmart TV Manual

864, pb 42 linear, pb 42 cf, 4415 ho
Hide thumbs Also See for CoolSmart TV:
Table of Contents

Advertisement

864 – Details

864 - Installation Overview

The CoolSmart system redirects the convective heat of the fireplace from the front of the unit, just above the
glass, to a location higher on the wall. The use of this kit allows for reduced clearance to combustibles and
accommodates TV installations closer to the fireplace or in a recessed cavity above the fireplace.
When using this kit, disregard the framing dimensions in the manual and follow the framing instructions shown on
page 3. In addition, the non-combustible facing height is reduced above the fireplace (see illustration below). All
other installation requirements for the fireplace must be followed as detailed in the appliance installation manual.
Ceiling
Min. 1-1/2" (39mm)
Min. 1-1/4" (32mm)
Max. 120"
(3048mm)
Min. 77"
(1956mm)
a
b
Page 2 of 33
CoolSmart TV
864, PB 42 Linear, PB 42 CF, 4415 HO
Television
Min. 1/4"
(7mm)
a
b
864 (31K,40K)
42-3/4" (1086mm)
36-3/4" (934mm)
17602029- 9/24/19
Sku# 98900779
Max. 4-1/4" (108mm)
Optional Recessed Pocket
Combustible Facing
Optional Non-Combustible
Facing Only
864 CleanFace (31K,40K)
49-1/4" (1251mm)
39-1/4" (997mm)
© Travis Industries, Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

98900779

Table of Contents