Download Print this page

Service Procedure - Rinnai REU-KBM3237FFUDHD-E Service Manual

Continuous flow water heater

Advertisement

Service Procedure

The service of the HDC1600 Series is fairly straight forward and should take
approximately no longer than 30 minutes. Please ensure you have an Electrode kit for
this model as this is required at least every 12-24 months depending on the usage.
Follow the steps below.
Isolate the appliance by the plug or fused spur and isolate the gas supply.
Ensure the appliance is cool enough for the Electrode Kit to be removed. Remove
the Spark Electrode, Ionisation Electrode and Thermo Couple and either clean or
replace.
Refit the Electrode Kit
Unplug the Fan Motor and remove the two screws highlighted below
Remove the Noise Filter from the fan using the 3 screws.
Inspect the Fan Motor Impeller and clean with a soft brush if required