Page of 2
Download Bookmark Comment

Rinnai REU-KA2530FFUD-US User Manual

Rinnai corp. water heater user manual.
Hide thumbs
   
RC80HPi (KA2530FFUD)
Type of Appliance
Condensing, Tankless, Temperature controlled, continuous flow,
gas hot water system, Energy Star Qualified
Rinnai model number
REU-KA2530FFUD-US
Operation / Installation
Forced combustion; indoor only
Minimum/Maximum Gas Rate (Input)
9,500 (Natural Gas), 10,300 (Propane) - 157,000 BTU/h
Electrical
Appliance:
AC 120 Volts - 60 Hz
Temperature Controller:
DC 12 Volts
Electrical Consumption
Normal
63 watts
Standby
2 watts
Anti-frost protection
220 watts
Direct electronic ignition
Ignition System
Hot Water Capacity
0.4 to 6.0 GPM (50° F rise)
0.4 to 8.0 GPM (35° F rise)
Temperature
98° - 120° F (factory default) Maximum temperature is selectable at
120° F or at 140° F; 98° - 185° F available with the MCC-91
controller for commercial and hydronic applications
120° F (factory default)
Temperature (without remote)
Natural or Propane (ensure unit matches gas type)
Approved Gas Types
Natural Gas: 97%
Propane: 97%
Thermal Efficiency
Energy Factor (EF)
Natural Gas: 0.96
Propane: 0.96
Service Connections
Gas supply: 3/4 inch MNPT
Cold water inlet: 3/4 inch MNPT
Hot water outlet: 3/4 inch MNPT
Water flow sensor, electronic water control and by-pass control
Water Flow Control
15 - 150 PSI (50 PSI or above is recommended for maximum flow)
Minimum/Maximum Water Supply Pressure
FLOW TABLE
10.0
9.0
8.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
0.0
0
25
50
75
100
125
150
delta T - Temperature Rise (ºF)
© 2010 Rinnai Corporation
RC80HPi-SP
8/2010

   Also See for Rinnai REU-KA2530FFUD-US

   Related Manuals for Rinnai REU-KA2530FFUD-US

   Summary of Contents for Rinnai REU-KA2530FFUD-US

  • Page 1

    Service Connections Water Flow Control Minimum/Maximum Water Supply Pressure FLOW TABLE 10.0 © 2010 Rinnai Corporation Condensing, Tankless, Temperature controlled, continuous flow, gas hot water system, Energy Star Qualified REU-KA2530FFUD-US Forced combustion; indoor only 9,500 (Natural Gas), 10,300 (Propane) - 157,000 BTU/h...

  • Page 2

    Local, state, provincial and federal codes must be adhered to prior to installation. WEIGHT: 63.9 lb (29 kg) DIMENSIONS Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us RC80HPi (KA2530FFUD) MC-91-1US (included)